Elcometer Canadian Distributor

1 800 463-4363
My Account
|

Elcometer 456 Separate Coating Thickness Gauge – Interchangeable Probes

Price range: $766.50 CAD through $1,927.20 CAD

• Up to 40 % faster than other gauges – 70 readings per minute!
• Apple / Android / Bluetooth compatible
•  Rapidly scan large surface areas

 

Flexible Dry Film Thickness Measurement with Interchangeable Probes

The Elcometer 456 Separate Coating Thickness Gauge is a professional digital gauge designed for fast, accurate and repeatable measurement of dry film thickness (DFT) on metal substrates. Unlike the integral version, the Separate model connects to a wide range of interchangeable external probes, providing greater flexibility for inspecting flat, curved, thin, rough and difficult-to-access surfaces.

Depending on the probe selected, the Elcometer 456 can measure coatings on ferrous, non-ferrous or both ferrous and non-ferrous metal substrates. The extensive probe range also allows coating thicknesses of up to 31 mm (1,220 mils) to be measured, making the system suitable for applications ranging from thin industrial finishes to very thick protective coatings.

Fast and Accurate Coating Thickness Measurements

The Elcometer 456 is designed for efficient inspection, taking more than 70 readings per minute with standard probes and more than 140 readings per minute when using a compatible Scan Probe. This allows inspectors to collect large quantities of dry film thickness data quickly across extensive coated surfaces.

The gauge provides accurate measurements on smooth, rough, thin and curved metal surfaces, with measurement accuracy of up to ±1% when used with the appropriate probe and calibration method.


ELCOMETER 456 COATING THICKNESS GAUGE MODEL SPECIFICATIONS
Model B Ferrous  0-1500μm (0-60mils) – base model for use with separate probes on ferrous substrates. Add to cart
Model S Ferrous  0-1500μm (0-60mils) – standard model for use with separate probes on ferrous substrates. Add to cart
Model T Ferrous  0-1500μm (0-60mils) – advanced model for use with separate probes on ferrous substrates. Add to cart
Model B Non ferrous 0-1500μm (0-60mils) – base model for for use with separate probes on non-ferrous substrates. Add to cart
Model S Non ferrous 0-1500μm (0-60mils) – full model for use with separate probes on non-ferrous substrates. Add to cart
Model T Non ferrous – 0-1500μm (0-60mils) – advanced model for use with separate probes on non-ferrous substrates. Add to cart
Model B Dual FNF 0-1500μm (0-60mils) – base model for use with separate probes on both ferrous & non-ferrous substrates. Add to cart
Model S Dual FNF 0-1500μm (0-60mils) – full model for use with separate probes on both ferrous & non-ferrous substrates Add to cart
Model T Dual FNF 0-1500μm (0-60mils) advanced model for use with separate probes on both ferrous & non-ferrous substrates. Add to cart

SELECT YOUR MODEL ON TOP OF THE PAGE TO VIEW THE PRICE

Choose the Probe for the Substrate and Application

One of the principal advantages of the Separate model is the ability to select a probe specifically suited to the inspection task. Probes are supplied separately and can be interchanged as required.

Ferrous (F) Probes

Ferrous probes use magnetic induction to measure non-magnetic coatings on magnetic metal substrates such as steel and iron. Typical applications include paint, powder coating, epoxy, enamel and other protective coatings applied over steel.

Non-Ferrous (N) Probes

Non-ferrous probes use the eddy current principle to measure non-conductive coatings on non-ferrous metals such as aluminium. They are suitable for many paint, powder coating and industrial finishing applications.

Dual FNF Probes

Dual FNF probes combine ferrous and non-ferrous measurement capability. They are particularly useful when inspectors routinely work with different metal substrates and want the flexibility to measure coatings on both ferrous and non-ferrous surfaces with the same gauge system.

Probe Options for Specialized Inspection

The Elcometer 456 Separate is compatible with an extensive selection of probe styles and measurement ranges. Probe options are available for general-purpose inspection as well as specialized applications involving small components, curved surfaces, restricted access and unusually thick coatings.

  • Standard straight probes for general coating inspection
  • Right-angle probes for restricted-access areas
  • Miniature probes for small components and confined locations
  • High-temperature probe options for suitable applications
  • Waterproof probe options for demanding environments
  • Scan probes for rapid collection of multiple readings
  • Thick-coating probes for extended measurement ranges
  • F, N and Dual FNF substrate configurations

Model B, Model S and Model T

The current Elcometer 456 Separate range is available in Model B, Model S and Model T. Each level provides the same core measurement platform, with additional inspection, statistical, memory and data-management capabilities available as you move through the range.

Model B

Model B provides the essential functions required for fast and accurate coating thickness inspection. It is well suited to users who primarily require immediate on-screen measurements without extensive batch data storage.

Model S

Model S adds enhanced statistical, calibration, memory and data-management functions. USB and Bluetooth® connectivity allow inspection readings to be transferred for analysis and reporting.

Model T

Model T is the most advanced configuration and is designed for inspectors who require extensive data collection and analysis. It can store up to 150,000 readings in 2,500 batches and provides advanced inspection and reporting capabilities for larger projects.

ElcoMaster® Data Management

Compatible Elcometer 456 models can transfer coating thickness measurements to ElcoMaster® Data Management Software using USB or Bluetooth®. Readings can be organized, analysed and incorporated into professional inspection reports, helping reduce the time required to document coating inspection projects.

Bluetooth® connectivity also allows compatible mobile devices to receive inspection data for field reporting and analysis.

Designed for Demanding Field Use

The Elcometer 456 is designed for regular use in industrial and protective coating environments. Its rugged enclosure is impact resistant, dust resistant and water resistant to an equivalent of IP64.

A bright 2.4 in (6 cm) colour TFT display provides clear measurement information. The screen automatically rotates through 0°, 90°, 180° and 270°, allowing readings to remain easy to view regardless of how the gauge is held.

Large positive-feedback buttons, an intuitive multilingual menu system and automatic screen brightness help make the gauge practical for continuous field inspection.

Key Features

    • Professional digital dry film thickness gauge
    • Separate interchangeable probe design for maximum measurement flexibility
    • Ferrous, non-ferrous and Dual FNF gauge configurations
    • Wide selection of specialized interchangeable probes
    • Measures coatings up to 31 mm (1,220 mils) with an appropriate probe
    • More than 70 readings per minute with standard probes
    • More than 140 readings per minute with a compatible Scan Probe
    • Accuracy up to ±1% with appropriate probe and calibration
    • Suitable for smooth, rough, thin and curved metal surfaces
    • Repeatable and reproducible measurements
    • Model T stores up to 150,000 readings in 2,500 batches
    • USB and Bluetooth® data output on compatible models
    • Compatible with ElcoMaster® data management software
    • Bright 2.4 in (6 cm) colour TFT display
    • Automatic display rotation
    • Menu structure available in more than 30 languages
    • Rugged, impact-resistant construction
    • Dust and water resistance equivalent to IP64
    • Factory calibrated
    • Supplied with a traceable test certificate

Gauge Specifications

Product Elcometer 456 Separate Coating Thickness Gauge
Available Models Model B, Model S, Model T
Substrate Options Ferrous (F), Non-Ferrous (N), Dual Ferrous/Non-Ferrous (FNF)
Probe Configuration External interchangeable probe – supplied separately
Reading Rate 70+ readings per minute; 140+ readings per minute with compatible Scan Probe
Maximum Measurement Range Up to 31 mm (1,220 mils), dependent on probe
Display 2.4 in (6 cm) QVGA colour TFT, 320 × 240 pixels
Environmental Protection Dust and water resistant, equivalent to IP64
Battery Type 2 × AA batteries; rechargeable AA batteries can also be used
Battery Life Approximately 24 hours continuous use at 1 reading per second with default settings and lithium batteries
Operating Temperature -10°C to 50°C (14°F to 122°F)
Gauge Dimensions 14.1 × 7.3 × 3.7 cm (5.55 × 2.87 × 1.46 in)
Gauge Weight 161 g (5.68 oz), including supplied batteries

Separate Gauge Part Numbers

Configuration Model B Model S Model T
Ferrous Separate A456CFBS A456CFSS A456CFTS
Non-Ferrous Separate A456CNBS A456CNSS A456CNTS
Dual FNF Separate A456CFNFBS A456CFNFSS A456CFNFTS

Note: The measurement probe is supplied separately. Select the appropriate probe according to the substrate, coating thickness range, component geometry and inspection requirements.

Standard Packing List

  • Elcometer 456 Separate gauge
  • Protective case
  • Wrist harness
  • 2 × AA batteries
  • Operating instructions
  • Traceable test certificate
  • USB cable with Models S and T
  • Screen protector with Models S and T
  • ElcoMaster® software support with Models S and T
  • Transit case with Model T

 

SLASH YOUR COSTS BY GETTING A COMPREHENSIVE KIT FOR YOUR PROJECT

FERROUS / NON-FERROUS METAL INSPECTION KIT  |  LARGER PROJECTS INSPECTION KIT 5  |  ALL-INCLUSIVE STRUCTURES ASSESSMENT KIT 6  |  SEE ALL ELCOMETER KITS AVAILABLE FOR SALE – SAVE BIG!

The importance of Coating Thickness Gauge Calibration

Formal quality systems, such as those described in ISO 9001, require coating thickness gauges to be properly controlled, logged, and calibrated. Increasingly, users are specifying that the readings taken by thickness gauges are traceable to National Standards.

In order to test the accuracy of a particular gauge, it is important to have traceable coating thickness standards. Elcometer offers a comprehensive range of certified foils together with zero test plates to ensure the accuracy of the coating thickness gauge. Get the best performance from the Elcometer 456 Coating Thickness Gauge and make the best use of the gauge’s ±1% accuracy by calibrating the coating thickness instrument to suit the application. This video will guide you through a range of calibration options for both the integral and the separate models.

Elcometer 456 accuracy and range

Integral Model Options

Scale 1

Range: 0-1500μm (0-60mils)

Accuracy*: ±1-3% or ±2.5μm (±0.1mil)

Resolution: 0.1μm: 0-100μm; 1μm: 100-1500μm (0.01mil: 0-5mils; 0.1mil: 5-60mils)

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI1

A456CFSI1

A456CFTI1

Elcometer 456 Non-Ferrous Integral

A456CNBI1

See separate gauges with

N2 PINIP™ Probe

See separate gauges with

N2 PINIP™ Probe

Elcometer 456 Dual FNF Integral

A456CFNFBI1

A456CFNFSI1

A456CFNFTI1

Scale 2

Range: 0-5mm (0-200mils)

Accuracy*: ±1-3% or ±20μm (±1.0mil)

Resolution: 1μm: 0-1mm; 10μm: 1-5mm (0.1mil: 0-50mils; 1mil: 50-200mils)

For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI2

See separate gauges with

F2 PINIP™ Probe

See separate gauges with

F2 PINIP™ Probe

Scale 3

Range: 0-13mm (0-500mils)

Accuracy*: ±1-3% or ±50μm (±2.0mils)

Resolution: 1μm: 0-2mm; 10μm: 2-13mm (0.1mil: 0-100mils; 1mil: 100-500mils)

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI3

See separate gauges with

F3 PINIP™ Probe

See separate gauges with

F3 PINIP™ Probe

Separate Model Options

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Separate

A456CFBS

A456CFSS

A456CFTS

Elcometer 456 Non-Ferrous Separate

A456CNBS

A456CNSS

A456CNTS

Elcometer 456 Dual FNF Separate

A456CFNFBS

A456CFNFSS

A456CFNFTS

Probes are supplied separately

* Whichever is the greater
● Certificate supplied as standard

Product Features ■ Standard □ Optional
Model B Model S Model T
Fast, accurate reading rate; 70+ readings per minute
Repeatable & reproducible measurements
Easy-to-use menu structure; in 30+ languages
Tough, impact, water & dust resistant; equivalent to IP64
Bright colour screen; with permanent backlight
Scratch & solvent-resistant display; 2.4″ (6cm) TFT
Large positive feedback buttons
USB power supply; via PC
Test certificate
2-year gauge warranty*
Automatic rotating display; 0°, 90°, 180° & 270°
Ambient light sensor; with adjustable auto brightness
Emergency light
Tap awake from sleep
Gauge software updates¹; via ElcoMaster® software
Data output

USB; to computer

Bluetooth®; to computer, Android™ & iOSǂ devices

On-screen statistics

Number of readings; η

Mean (average); x

Standard deviation; ó

Highest reading; Hi

Lowest reading; Lo

Coefficient of variation; CV%

Elcometer index value²; EIV

Nominal dry film thickness; NDFT

IMO PSPC; %>NDFT, %>90

High & low limits; definable audible & visual alarms

Number above high limit;

Number below low limit;

Live reading trend graph; in batch mode
ElcoMaster® software & USB cable
Replaceable screen protectors
Protective case
Plastic transit case
Integral models; with automatic gauge switch on

Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³

F, N, FNF F, N, FNF F, N, FNF

Measurement range

0-13mm
0-500mils
 0-1500μm
0-60mils
 0-1500μm
0-60mils
Separate models; with automatic probe recognition

Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³

F, N, FNF F, N, FNF F, N, FNF

Measurement range

0-31mm
0-1220mils
0-31mm
0-1220mils
0-31mm
0-1220mils
On-screen calibration instructions; in 30+ languages
Multiple calibration methods

Factory; resets to the factory calibration

2-point; for smooth and rough surfaces

1-point; zero calibration

Zero offset4for calibration according to ISO19840

Predefined calibration & measurement methods

ISO, SSPC PA2, Swedish, Australian

Automatic calibration; for rapid calibration
Calibration memory type; gauge (g) or gauge & batch (gb) g gb gb
Number of batches; with unique calibrations 1 2,500
Calibration memories; 3 user-programmable memories
Measurement outside calibration warning
Calibration lock; with optional PIN code unlock
Delete last reading
Gauge memory; the number of readings Last 5 1,500 150,000
Individual batch calibrations; sent to PC via ElcoMaster®
Limits; user-definable audible & visual pass/fail warnings

Gauge (g) or gauge & batch specific (gb) limits

g gb
Date and time stamp
Batch types; normal, counted average, IMO PSPC

Navsea Mode

Batch review graph
Review, clear & delete batches
Copy batches and calibration settings
Alpha-numeric batch names; user-definable on the gauge
Scan & Auto-Repeat Modes; with Scan probe connected
Fixed batch size mode; with batch linking

 

Technical Specifications
Display information 2.4″ (6cm) QVGA colour TFT display, 320 x 240 pixels
Battery type 2 x AA dry cell batteries, rechargeable batteries can also be used
Battery life ~24 hours of continuous use at 1 reading per second5
Gauge dimensions
(h x w x d)
141 x 73 x 37mm (5.55 x 2.87 x 1.46″)
Gauge weight 161g (5.68oz) including supplied batteries
Operating temperature -10 to 50°C (14 to 122°F)
Packing List Elcometer 456 gauge, calibration foils (integrals only), wrist harness, transit case (T), protective case (B, S, T),
1 x screen protectors (S, T), 2 x AA batteries, operating instructions, USB cable (S, T), ElcoMaster® software (S, T)

5 Using default settings & lithium batteries, alkaline or rechargeable batteries may differ

STANDARDS:
AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091, ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984, ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2178, ISO 2360, ISO 2808-6A, ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32

Standards in grey have been superseded but are still recognised in some industries.

Q&A

What is the main advantage of the Elcometer 456 Separate over the Integral model?

The Separate model uses an external interchangeable probe. This allows the operator to select different probe shapes, measurement ranges and substrate types for different inspection jobs, making it more flexible for specialized applications and difficult-to-access surfaces.

Does the Elcometer 456 Separate include a probe?

No. The Separate gauge and measurement probe are selected separately. This allows the correct ferrous, non-ferrous or Dual FNF probe and measurement range to be chosen for the application.

Which probe should be used for coatings on steel?

A ferrous (F) probe is normally used to measure non-magnetic coatings such as paint, epoxy and powder coating over magnetic substrates such as steel or iron.

Which probe should be used for coatings on aluminium?

A non-ferrous (N) probe is used for non-conductive coatings on non-ferrous metal substrates such as aluminium. A Dual FNF probe is a practical alternative when both steel and non-ferrous metals are regularly inspected.

Can the Elcometer 456 measure very thick protective coatings?

Yes. The Separate system’s extensive probe range allows measurements up to 31 mm (1,220 mils) with an appropriate probe. The actual measurement range and accuracy depend on the probe selected.

Is the Separate model suitable for curved or difficult-to-reach surfaces?

Yes. This is one of its principal advantages. Specialized probe designs are available for curved surfaces, small components and restricted-access locations where an integral gauge may be less convenient.

Can inspection readings be transferred to a computer or mobile device?

Models with the appropriate data-output functions can transfer readings using USB or Bluetooth® for analysis and reporting with ElcoMaster® software and compatible devices.

Which Elcometer 456 model is best for extensive inspection projects?

Model T offers the most extensive data-management capabilities and can store up to 150,000 readings in 2,500 batches, making it particularly useful for projects requiring large amounts of documented inspection data.

 

QUICK TIP:

How to take a reading with Elcometer 456:

1. Whilst holding the gauge perpendicular, gently place the probe onto the surface.
· Do not drag the probe across the surface or bang the probe down hard onto the surface as this will damage the probe tip resulting in inaccurate readings.
· >1500µm’ (’>60mils’) indicates a reading over the probe range.

2. For subsequent readings, lift the probe off and then replace it onto the coated surface.
· Do not allow the probe to hover over the surface as this could result in a false reading.

The first reading taken is displayed next to ‘1′, the second next to ‘2′ etc. When the third reading has been taken, the average (mean, xbar) of the three individual readings displayed is shown (X:).

The average (mean, xbar) reading is cleared when a fourth reading is taken.

By selecting ‘Send Individual Readings’ or ‘Send Mean (xbar) Reading’ via Menu/Bluetooth, the user can choose to transfer the individual readings or just the average (mean, xbar) reading values to ® ® ElcoMaster or ElcoMaster Mobile Apps – see Section 7 on page 7.

**Note: The Elcometer 456 Separate gauges require the use of a compatible probe – Sold Separately.**

Download Data Sheet
Download Instruction Manual

You may be also interested in:

Elcometer 456 Integral Digital Coating Thickness Gauge

Flexible Dry Film Thickness Measurement with Interchangeable Probes

The Elcometer 456 Separate Coating Thickness Gauge is a professional digital gauge designed for fast, accurate and repeatable measurement of dry film thickness (DFT) on metal substrates. Unlike the integral version, the Separate model connects to a wide range of interchangeable external probes, providing greater flexibility for inspecting flat, curved, thin, rough and difficult-to-access surfaces.

Depending on the probe selected, the Elcometer 456 can measure coatings on ferrous, non-ferrous or both ferrous and non-ferrous metal substrates. The extensive probe range also allows coating thicknesses of up to 31 mm (1,220 mils) to be measured, making the system suitable for applications ranging from thin industrial finishes to very thick protective coatings.

Fast and Accurate Coating Thickness Measurements

The Elcometer 456 is designed for efficient inspection, taking more than 70 readings per minute with standard probes and more than 140 readings per minute when using a compatible Scan Probe. This allows inspectors to collect large quantities of dry film thickness data quickly across extensive coated surfaces.

The gauge provides accurate measurements on smooth, rough, thin and curved metal surfaces, with measurement accuracy of up to ±1% when used with the appropriate probe and calibration method.


ELCOMETER 456 COATING THICKNESS GAUGE MODEL SPECIFICATIONS
Model B Ferrous  0-1500μm (0-60mils) – base model for use with separate probes on ferrous substrates. Add to cart
Model S Ferrous  0-1500μm (0-60mils) – standard model for use with separate probes on ferrous substrates. Add to cart
Model T Ferrous  0-1500μm (0-60mils) – advanced model for use with separate probes on ferrous substrates. Add to cart
Model B Non ferrous 0-1500μm (0-60mils) – base model for for use with separate probes on non-ferrous substrates. Add to cart
Model S Non ferrous 0-1500μm (0-60mils) – full model for use with separate probes on non-ferrous substrates. Add to cart
Model T Non ferrous – 0-1500μm (0-60mils) – advanced model for use with separate probes on non-ferrous substrates. Add to cart
Model B Dual FNF 0-1500μm (0-60mils) – base model for use with separate probes on both ferrous & non-ferrous substrates. Add to cart
Model S Dual FNF 0-1500μm (0-60mils) – full model for use with separate probes on both ferrous & non-ferrous substrates Add to cart
Model T Dual FNF 0-1500μm (0-60mils) advanced model for use with separate probes on both ferrous & non-ferrous substrates. Add to cart

SELECT YOUR MODEL ON TOP OF THE PAGE TO VIEW THE PRICE

Choose the Probe for the Substrate and Application

One of the principal advantages of the Separate model is the ability to select a probe specifically suited to the inspection task. Probes are supplied separately and can be interchanged as required.

Ferrous (F) Probes

Ferrous probes use magnetic induction to measure non-magnetic coatings on magnetic metal substrates such as steel and iron. Typical applications include paint, powder coating, epoxy, enamel and other protective coatings applied over steel.

Non-Ferrous (N) Probes

Non-ferrous probes use the eddy current principle to measure non-conductive coatings on non-ferrous metals such as aluminium. They are suitable for many paint, powder coating and industrial finishing applications.

Dual FNF Probes

Dual FNF probes combine ferrous and non-ferrous measurement capability. They are particularly useful when inspectors routinely work with different metal substrates and want the flexibility to measure coatings on both ferrous and non-ferrous surfaces with the same gauge system.

Probe Options for Specialized Inspection

The Elcometer 456 Separate is compatible with an extensive selection of probe styles and measurement ranges. Probe options are available for general-purpose inspection as well as specialized applications involving small components, curved surfaces, restricted access and unusually thick coatings.

  • Standard straight probes for general coating inspection
  • Right-angle probes for restricted-access areas
  • Miniature probes for small components and confined locations
  • High-temperature probe options for suitable applications
  • Waterproof probe options for demanding environments
  • Scan probes for rapid collection of multiple readings
  • Thick-coating probes for extended measurement ranges
  • F, N and Dual FNF substrate configurations

Model B, Model S and Model T

The current Elcometer 456 Separate range is available in Model B, Model S and Model T. Each level provides the same core measurement platform, with additional inspection, statistical, memory and data-management capabilities available as you move through the range.

Model B

Model B provides the essential functions required for fast and accurate coating thickness inspection. It is well suited to users who primarily require immediate on-screen measurements without extensive batch data storage.

Model S

Model S adds enhanced statistical, calibration, memory and data-management functions. USB and Bluetooth® connectivity allow inspection readings to be transferred for analysis and reporting.

Model T

Model T is the most advanced configuration and is designed for inspectors who require extensive data collection and analysis. It can store up to 150,000 readings in 2,500 batches and provides advanced inspection and reporting capabilities for larger projects.

ElcoMaster® Data Management

Compatible Elcometer 456 models can transfer coating thickness measurements to ElcoMaster® Data Management Software using USB or Bluetooth®. Readings can be organized, analysed and incorporated into professional inspection reports, helping reduce the time required to document coating inspection projects.

Bluetooth® connectivity also allows compatible mobile devices to receive inspection data for field reporting and analysis.

Designed for Demanding Field Use

The Elcometer 456 is designed for regular use in industrial and protective coating environments. Its rugged enclosure is impact resistant, dust resistant and water resistant to an equivalent of IP64.

A bright 2.4 in (6 cm) colour TFT display provides clear measurement information. The screen automatically rotates through 0°, 90°, 180° and 270°, allowing readings to remain easy to view regardless of how the gauge is held.

Large positive-feedback buttons, an intuitive multilingual menu system and automatic screen brightness help make the gauge practical for continuous field inspection.

Key Features

    • Professional digital dry film thickness gauge
    • Separate interchangeable probe design for maximum measurement flexibility
    • Ferrous, non-ferrous and Dual FNF gauge configurations
    • Wide selection of specialized interchangeable probes
    • Measures coatings up to 31 mm (1,220 mils) with an appropriate probe
    • More than 70 readings per minute with standard probes
    • More than 140 readings per minute with a compatible Scan Probe
    • Accuracy up to ±1% with appropriate probe and calibration
    • Suitable for smooth, rough, thin and curved metal surfaces
    • Repeatable and reproducible measurements
    • Model T stores up to 150,000 readings in 2,500 batches
    • USB and Bluetooth® data output on compatible models
    • Compatible with ElcoMaster® data management software
    • Bright 2.4 in (6 cm) colour TFT display
    • Automatic display rotation
    • Menu structure available in more than 30 languages
    • Rugged, impact-resistant construction
    • Dust and water resistance equivalent to IP64
    • Factory calibrated
    • Supplied with a traceable test certificate

Gauge Specifications

Product Elcometer 456 Separate Coating Thickness Gauge
Available Models Model B, Model S, Model T
Substrate Options Ferrous (F), Non-Ferrous (N), Dual Ferrous/Non-Ferrous (FNF)
Probe Configuration External interchangeable probe – supplied separately
Reading Rate 70+ readings per minute; 140+ readings per minute with compatible Scan Probe
Maximum Measurement Range Up to 31 mm (1,220 mils), dependent on probe
Display 2.4 in (6 cm) QVGA colour TFT, 320 × 240 pixels
Environmental Protection Dust and water resistant, equivalent to IP64
Battery Type 2 × AA batteries; rechargeable AA batteries can also be used
Battery Life Approximately 24 hours continuous use at 1 reading per second with default settings and lithium batteries
Operating Temperature -10°C to 50°C (14°F to 122°F)
Gauge Dimensions 14.1 × 7.3 × 3.7 cm (5.55 × 2.87 × 1.46 in)
Gauge Weight 161 g (5.68 oz), including supplied batteries

Separate Gauge Part Numbers

Configuration Model B Model S Model T
Ferrous Separate A456CFBS A456CFSS A456CFTS
Non-Ferrous Separate A456CNBS A456CNSS A456CNTS
Dual FNF Separate A456CFNFBS A456CFNFSS A456CFNFTS

Note: The measurement probe is supplied separately. Select the appropriate probe according to the substrate, coating thickness range, component geometry and inspection requirements.

Standard Packing List

  • Elcometer 456 Separate gauge
  • Protective case
  • Wrist harness
  • 2 × AA batteries
  • Operating instructions
  • Traceable test certificate
  • USB cable with Models S and T
  • Screen protector with Models S and T
  • ElcoMaster® software support with Models S and T
  • Transit case with Model T

 

SLASH YOUR COSTS BY GETTING A COMPREHENSIVE KIT FOR YOUR PROJECT

FERROUS / NON-FERROUS METAL INSPECTION KIT  |  LARGER PROJECTS INSPECTION KIT 5  |  ALL-INCLUSIVE STRUCTURES ASSESSMENT KIT 6  |  SEE ALL ELCOMETER KITS AVAILABLE FOR SALE – SAVE BIG!

The importance of Coating Thickness Gauge Calibration

Formal quality systems, such as those described in ISO 9001, require coating thickness gauges to be properly controlled, logged, and calibrated. Increasingly, users are specifying that the readings taken by thickness gauges are traceable to National Standards.

In order to test the accuracy of a particular gauge, it is important to have traceable coating thickness standards. Elcometer offers a comprehensive range of certified foils together with zero test plates to ensure the accuracy of the coating thickness gauge. Get the best performance from the Elcometer 456 Coating Thickness Gauge and make the best use of the gauge’s ±1% accuracy by calibrating the coating thickness instrument to suit the application. This video will guide you through a range of calibration options for both the integral and the separate models.

Elcometer 456 accuracy and range

Integral Model Options

Scale 1

Range: 0-1500μm (0-60mils)

Accuracy*: ±1-3% or ±2.5μm (±0.1mil)

Resolution: 0.1μm: 0-100μm; 1μm: 100-1500μm (0.01mil: 0-5mils; 0.1mil: 5-60mils)

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI1

A456CFSI1

A456CFTI1

Elcometer 456 Non-Ferrous Integral

A456CNBI1

See separate gauges with

N2 PINIP™ Probe

See separate gauges with

N2 PINIP™ Probe

Elcometer 456 Dual FNF Integral

A456CFNFBI1

A456CFNFSI1

A456CFNFTI1

Scale 2

Range: 0-5mm (0-200mils)

Accuracy*: ±1-3% or ±20μm (±1.0mil)

Resolution: 1μm: 0-1mm; 10μm: 1-5mm (0.1mil: 0-50mils; 1mil: 50-200mils)

For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI2

See separate gauges with

F2 PINIP™ Probe

See separate gauges with

F2 PINIP™ Probe

Scale 3

Range: 0-13mm (0-500mils)

Accuracy*: ±1-3% or ±50μm (±2.0mils)

Resolution: 1μm: 0-2mm; 10μm: 2-13mm (0.1mil: 0-100mils; 1mil: 100-500mils)

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI3

See separate gauges with

F3 PINIP™ Probe

See separate gauges with

F3 PINIP™ Probe

Separate Model Options

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Separate

A456CFBS

A456CFSS

A456CFTS

Elcometer 456 Non-Ferrous Separate

A456CNBS

A456CNSS

A456CNTS

Elcometer 456 Dual FNF Separate

A456CFNFBS

A456CFNFSS

A456CFNFTS

Probes are supplied separately

* Whichever is the greater
● Certificate supplied as standard

Product Features ■ Standard □ Optional
Model B Model S Model T
Fast, accurate reading rate; 70+ readings per minute
Repeatable & reproducible measurements
Easy-to-use menu structure; in 30+ languages
Tough, impact, water & dust resistant; equivalent to IP64
Bright colour screen; with permanent backlight
Scratch & solvent-resistant display; 2.4″ (6cm) TFT
Large positive feedback buttons
USB power supply; via PC
Test certificate
2-year gauge warranty*
Automatic rotating display; 0°, 90°, 180° & 270°
Ambient light sensor; with adjustable auto brightness
Emergency light
Tap awake from sleep
Gauge software updates¹; via ElcoMaster® software
Data output

USB; to computer

Bluetooth®; to computer, Android™ & iOSǂ devices

On-screen statistics

Number of readings; η

Mean (average); x

Standard deviation; ó

Highest reading; Hi

Lowest reading; Lo

Coefficient of variation; CV%

Elcometer index value²; EIV

Nominal dry film thickness; NDFT

IMO PSPC; %>NDFT, %>90

High & low limits; definable audible & visual alarms

Number above high limit;

Number below low limit;

Live reading trend graph; in batch mode
ElcoMaster® software & USB cable
Replaceable screen protectors
Protective case
Plastic transit case
Integral models; with automatic gauge switch on

Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³

F, N, FNF F, N, FNF F, N, FNF

Measurement range

0-13mm
0-500mils
 0-1500μm
0-60mils
 0-1500μm
0-60mils
Separate models; with automatic probe recognition

Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³

F, N, FNF F, N, FNF F, N, FNF

Measurement range

0-31mm
0-1220mils
0-31mm
0-1220mils
0-31mm
0-1220mils
On-screen calibration instructions; in 30+ languages
Multiple calibration methods

Factory; resets to the factory calibration

2-point; for smooth and rough surfaces

1-point; zero calibration

Zero offset4for calibration according to ISO19840

Predefined calibration & measurement methods

ISO, SSPC PA2, Swedish, Australian

Automatic calibration; for rapid calibration
Calibration memory type; gauge (g) or gauge & batch (gb) g gb gb
Number of batches; with unique calibrations 1 2,500
Calibration memories; 3 user-programmable memories
Measurement outside calibration warning
Calibration lock; with optional PIN code unlock
Delete last reading
Gauge memory; the number of readings Last 5 1,500 150,000
Individual batch calibrations; sent to PC via ElcoMaster®
Limits; user-definable audible & visual pass/fail warnings

Gauge (g) or gauge & batch specific (gb) limits

g gb
Date and time stamp
Batch types; normal, counted average, IMO PSPC

Navsea Mode

Batch review graph
Review, clear & delete batches
Copy batches and calibration settings
Alpha-numeric batch names; user-definable on the gauge
Scan & Auto-Repeat Modes; with Scan probe connected
Fixed batch size mode; with batch linking

 

Technical Specifications
Display information 2.4″ (6cm) QVGA colour TFT display, 320 x 240 pixels
Battery type 2 x AA dry cell batteries, rechargeable batteries can also be used
Battery life ~24 hours of continuous use at 1 reading per second5
Gauge dimensions
(h x w x d)
141 x 73 x 37mm (5.55 x 2.87 x 1.46″)
Gauge weight 161g (5.68oz) including supplied batteries
Operating temperature -10 to 50°C (14 to 122°F)
Packing List Elcometer 456 gauge, calibration foils (integrals only), wrist harness, transit case (T), protective case (B, S, T),
1 x screen protectors (S, T), 2 x AA batteries, operating instructions, USB cable (S, T), ElcoMaster® software (S, T)

5 Using default settings & lithium batteries, alkaline or rechargeable batteries may differ

STANDARDS:
AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091, ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984, ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2178, ISO 2360, ISO 2808-6A, ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32

Standards in grey have been superseded but are still recognised in some industries.

Q&A

What is the main advantage of the Elcometer 456 Separate over the Integral model?

The Separate model uses an external interchangeable probe. This allows the operator to select different probe shapes, measurement ranges and substrate types for different inspection jobs, making it more flexible for specialized applications and difficult-to-access surfaces.

Does the Elcometer 456 Separate include a probe?

No. The Separate gauge and measurement probe are selected separately. This allows the correct ferrous, non-ferrous or Dual FNF probe and measurement range to be chosen for the application.

Which probe should be used for coatings on steel?

A ferrous (F) probe is normally used to measure non-magnetic coatings such as paint, epoxy and powder coating over magnetic substrates such as steel or iron.

Which probe should be used for coatings on aluminium?

A non-ferrous (N) probe is used for non-conductive coatings on non-ferrous metal substrates such as aluminium. A Dual FNF probe is a practical alternative when both steel and non-ferrous metals are regularly inspected.

Can the Elcometer 456 measure very thick protective coatings?

Yes. The Separate system’s extensive probe range allows measurements up to 31 mm (1,220 mils) with an appropriate probe. The actual measurement range and accuracy depend on the probe selected.

Is the Separate model suitable for curved or difficult-to-reach surfaces?

Yes. This is one of its principal advantages. Specialized probe designs are available for curved surfaces, small components and restricted-access locations where an integral gauge may be less convenient.

Can inspection readings be transferred to a computer or mobile device?

Models with the appropriate data-output functions can transfer readings using USB or Bluetooth® for analysis and reporting with ElcoMaster® software and compatible devices.

Which Elcometer 456 model is best for extensive inspection projects?

Model T offers the most extensive data-management capabilities and can store up to 150,000 readings in 2,500 batches, making it particularly useful for projects requiring large amounts of documented inspection data.

 

QUICK TIP:

How to take a reading with Elcometer 456:

1. Whilst holding the gauge perpendicular, gently place the probe onto the surface.
· Do not drag the probe across the surface or bang the probe down hard onto the surface as this will damage the probe tip resulting in inaccurate readings.
· >1500µm’ (’>60mils’) indicates a reading over the probe range.

2. For subsequent readings, lift the probe off and then replace it onto the coated surface.
· Do not allow the probe to hover over the surface as this could result in a false reading.

The first reading taken is displayed next to ‘1′, the second next to ‘2′ etc. When the third reading has been taken, the average (mean, xbar) of the three individual readings displayed is shown (X:).

The average (mean, xbar) reading is cleared when a fourth reading is taken.

By selecting ‘Send Individual Readings’ or ‘Send Mean (xbar) Reading’ via Menu/Bluetooth, the user can choose to transfer the individual readings or just the average (mean, xbar) reading values to ® ® ElcoMaster or ElcoMaster Mobile Apps – see Section 7 on page 7.

**Note: The Elcometer 456 Separate gauges require the use of a compatible probe – Sold Separately.**

Download Data Sheet
Download Instruction Manual

You may be also interested in:

Elcometer 456 Integral Digital Coating Thickness Gauge