All Elcometer 456 telescopic probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application
Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.
Ideal for higher resolution & accuracy on thin coatings Scale, 2 gauges can be switched to the Scale 1 mode measurement performance. Great for taking readings in areas with restricted access or head clearance.
Elcometer 456 telescopic probes at a great price
- 22-48″
- Range: 0-200 mils (0-5mm)
- Accuracy*: ±1-3% or ±1.0 mil (±20µm)
- Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm)
- Minimum convex surface radius 4mm (0.16″)
- Minimum concave surface radius 25mm (0.98″)
- Minimum headroom 36mm (1.42″)
- Minimum sample diameter: 8mm (0.32″)
*Whichever is greater
Ferrous probes measure nonmagnetic coatings on ferromagnetic substrates. Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure nonconductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.
Unless stated, Elcometer separate probes have a maximum operating temperature of 150°C (300°F), PINIP™ probes have a maximum operating temperature of 80°C (176°F).
Every Elcometer 456 gauge and the separate probe is supplied with a Test Certificate free of charge. For separate gauges, the test measurements are generated using factory reference probes.
All Elcometer 456 telescopic probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application
Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.
Ideal for higher resolution & accuracy on thin coatings Scale, 2 gauges can be switched to the Scale 1 mode measurement performance. Great for taking readings in areas with restricted access or head clearance.
Elcometer 456 telescopic probes at a great price
- 22-48″
- Range: 0-200 mils (0-5mm)
- Accuracy*: ±1-3% or ±1.0 mil (±20µm)
- Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm)
- Minimum convex surface radius 4mm (0.16″)
- Minimum concave surface radius 25mm (0.98″)
- Minimum headroom 36mm (1.42″)
- Minimum sample diameter: 8mm (0.32″)
*Whichever is greater
Ferrous probes measure nonmagnetic coatings on ferromagnetic substrates. Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure nonconductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.
Unless stated, Elcometer separate probes have a maximum operating temperature of 150°C (300°F), PINIP™ probes have a maximum operating temperature of 80°C (176°F).
Every Elcometer 456 gauge and the separate probe is supplied with a Test Certificate free of charge. For separate gauges, the test measurements are generated using factory reference probes.