Elcometer Canadian Distributor

1 800 463-4363
My Account
|
Elcometer distributor - Test Coatings

Elcometer 456 telescopic probes

$1,240.44 CAD

  1. Minimum convex surface radius 4mm (0.16″)
  2. Minimum concave surface radius 25mm (0.98″)
  3. Minimum headroom 36mm (1.42″)

To view Elcometer 456 price per model please choose below
or call 1 800 463-4363

 

All Elcometer 456 telescopic probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application

Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.

Ideal for higher resolution & accuracy on thin coatings Scale, 2 gauges can be switched to the Scale 1 mode measurement performance. Great for taking readings in areas with restricted access or head clearance.

Elcometer 456 telescopic probes at a great price

  1. 22-48″
  2. Range: 0-200 mils (0-5mm)
  3. Accuracy*: ±1-3% or ±1.0 mil (±20µm)
  4. Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm)
  5. Minimum convex surface radius 4mm (0.16″)
  6. Minimum concave surface radius 25mm (0.98″)
  7. Minimum headroom 36mm (1.42″)
  8. Minimum sample diameter: 8mm (0.32″)

*Whichever is greater

Ferrous probes measure nonmagnetic coatings on ferromagnetic substrates. Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure nonconductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.

Unless stated, Elcometer separate probes have a maximum operating temperature of 150°C (300°F), PINIP™ probes have a maximum operating temperature of 80°C (176°F).

Every Elcometer 456 gauge and the separate probe is supplied with a Test Certificate free of charge. For separate gauges, the test measurements are generated using factory reference probes.

 

1-Free-shipping

Elcometer 456 Integral Digital Coating Thickness Gauge

All Elcometer 456 telescopic probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application

Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.

Ideal for higher resolution & accuracy on thin coatings Scale, 2 gauges can be switched to the Scale 1 mode measurement performance. Great for taking readings in areas with restricted access or head clearance.

Elcometer 456 telescopic probes at a great price

  1. 22-48″
  2. Range: 0-200 mils (0-5mm)
  3. Accuracy*: ±1-3% or ±1.0 mil (±20µm)
  4. Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm)
  5. Minimum convex surface radius 4mm (0.16″)
  6. Minimum concave surface radius 25mm (0.98″)
  7. Minimum headroom 36mm (1.42″)
  8. Minimum sample diameter: 8mm (0.32″)

*Whichever is greater

Ferrous probes measure nonmagnetic coatings on ferromagnetic substrates. Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure nonconductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.

Unless stated, Elcometer separate probes have a maximum operating temperature of 150°C (300°F), PINIP™ probes have a maximum operating temperature of 80°C (176°F).

Every Elcometer 456 gauge and the separate probe is supplied with a Test Certificate free of charge. For separate gauges, the test measurements are generated using factory reference probes.

 

1-Free-shipping

Elcometer 456 Integral Digital Coating Thickness Gauge