Elcometer 456 Digital Coating Thickness Gauge with detachable probe variety

$762.01 CAD$1,883.58 CAD

ā€¢ Up to 40 % faster than other gauges – 70 readings per minute!
ā€¢ Apple / Android / Bluetooth compatible
ā€¢Ā  Rapidly scan large surface areas

 

Elcometer 456 with probe is ideal for structures and surfaces assessment.

Ā Also used for aluminum and other non-magnetic metal surfaces. With a reading rate of 140 readings per minute, the Elcometer 456 with probe allows you to inspect more coatings in less time.


ELCOMETER 456 COATING THICKNESS GAUGE MODEL SPECIFICATIONS
Model B FerrousĀ  0-1500Ī¼m (0-60mils) – base model for use with separate probes on ferrous substrates. Add to cart
Model S FerrousĀ  0-1500Ī¼m (0-60mils) – standard model for use with separate probes on ferrous substrates. Add to cart
Model T FerrousĀ  0-1500Ī¼m (0-60mils) – advanced model for use with separate probes on ferrous substrates. Add to cart
Model B Non ferrous 0-1500Ī¼m (0-60mils) – base model for for use with separate probes on non-ferrous substrates. Add to cart
Model S Non ferrous 0-1500Ī¼m (0-60mils) – full model for use with separate probes on non-ferrous substrates. Add to cart
Model T Non ferrous – 0-1500Ī¼m (0-60mils) – advanced model for use with separate probes on non-ferrous substrates. Add to cart
Model B Dual FNF 0-1500Ī¼m (0-60mils) – base model for use with separate probes on both ferrous & non-ferrous substrates. Add to cart
Model S Dual FNF 0-1500Ī¼m (0-60mils) – full model for use with separate probes on both ferrous & non-ferrous substrates Add to cart
Model T Dual FNF 0-1500Ī¼m (0-60mils) advanced model for use with separate probes on both ferrous & non-ferrous substrates. Add to cart

SELECT YOUR MODEL ON TOP OF THE PAGE TO VIEW THE PRICE


Repeatable readings on smooth, rough, thin and curved surfaces

With a wide range of probes available, you obtain great flexibility of access to difficult-to-reach surfaces. All probes are fully interchangeable; while ferrous gauges accept any ferrous probe and non-ferrous gauges accept any non-ferrous probes the dual FNFĀ gauges accept all ferrous, non-ferrous, and dualĀ FNF probes.Ā  Our most advanced model, Model T features memory, alpha-numeric batching, and BluetoothĀ® communication.

Fast Coating Thickness Measurements

The Elcometer 456 Coating Thickness Gauge enhances efficiency by providing 70+ dry film thickness readings per minute (140+ per minute when using a scan probe). The Elcometer 456 mil gauge has multiple calibration memories and alpha numeric batch i

Efficiently scans large surface areas

When using Scan or Auto Repeat Mode, you can get a lot of sampling done quickly, without affecting accuracy. Our highly durable probe cap allows to rapidly scan large surface areas without damaging the probe or the coating.

User-friendly

ā€¢ Large buttons ideal for gloved hands
ā€¢ Multiple languages menus
ā€¢ High contrast colour LCD with auto-rotate
ā€¢ High and low reading limit indicators
ā€¢ Factory calibrated for immediate use
ā€¢ Thickness measurement capability to Ā±1%
ā€¢ Can be used in accordance with National & International Standards
ā€¢ Temperature stable measurements
ā€¢ Increased reading resolution for thin coatings

How reliable is Elcometer 456?

ā€¢ 2-year gauge warranty
ā€¢ Comes with fully traceable test certificates
ā€¢ Batch date and time stamp facility
ā€¢ Rugged casing, suitable for use in harsh environment
ā€¢ Sealed, heavy-duty and impact-resistant
ā€¢ Dust and waterproof equivalent to IP64
ā€¢ Scratch and solvent resistant display
ā€¢ Durable gauge and probe construction
ā€¢ Suitable for harsh environments

Efficient

ā€¢ The fast reading rate of 70+ per minute, 140+ per minute with Scan Probe
ā€¢ Multiple calibration memories.
ā€¢ Alphanumeric batch identification
ā€¢ User-selectable calibration methods

Memory & versatility

ā€¢ Wide range of interchangeable probes
ā€¢ USB and BluetoothĀ® data output to iPhone* or Androidā„¢ devices
ā€¢ Stores up to 150,000 readings in 2,500 batches
ā€¢ Measures up to 31mm (1220mils) of coating on metal substrates

SLASH YOUR COSTSĀ BY GETTING A COMPREHENSIVE KIT FOR YOUR PROJECT

FERROUS / NON-FERROUS METAL INSPECTION KITĀ  |Ā  LARGER PROJECTS INSPECTION KIT 5Ā  |Ā  ALL-INCLUSIVE STRUCTURES ASSEESSMENT KIT 6Ā  | Ā SEE ALL ELCOMETER KITS AVAILABLE FOR SALE – SAVE BIG!

The importance of Coating Thickness Gauge Calibration

Formal quality systems, such as those described in ISO 9001, require coating thickness gauges to be properly controlled, logged, and calibrated. Increasingly, users are specifying that the readings taken by thickness gauges are traceable to National Standards.

In order to test the accuracy of a particular gauge, it is important to have traceable coating thickness standards. Elcometer offers a comprehensive range of certified foils together with zero test plates to ensure the accuracy of the coating thickness gauge. Get the best performance from the Elcometer 456 Coating Thickness Gauge and make the best use of the gaugeā€™s Ā±1% accuracy by calibrating the coating thickness instrument to suit the application. This video will guide you through a range of calibration options for both the integral and the separate models.

Elcometer 456 accuracy and range

Integral Model Options

Scale 1

Range: 0-1500Ī¼m (0-60mils)

Accuracy*: Ā±1-3% or Ā±2.5Ī¼m (Ā±0.1mil)

Resolution: 0.1Ī¼m: 0-100Ī¼m; 1Ī¼m: 100-1500Ī¼m (0.01mil: 0-5mils; 0.1mil: 5-60mils)

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI1

A456CFSI1

A456CFTI1

ā—

Elcometer 456 Non-Ferrous Integral

A456CNBI1

See separate gauges with

N2 PINIPā„¢ Probe

See separate gauges with

N2 PINIPā„¢ Probe

ā—

Elcometer 456 Dual FNF Integral

A456CFNFBI1

A456CFNFSI1

A456CFNFTI1

ā—

Scale 2

Range: 0-5mm (0-200mils)

Accuracy*: Ā±1-3% or Ā±20Ī¼m (Ā±1.0mil)

Resolution: 1Ī¼m: 0-1mm; 10Ī¼m: 1-5mm (0.1mil: 0-50mils; 1mil: 50-200mils)

For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI2

See separate gauges with

F2 PINIPā„¢ Probe

See separate gauges with

F2 PINIPā„¢ Probe

ā—

Scale 3

Range: 0-13mm (0-500mils)

Accuracy*: Ā±1-3% or Ā±50Ī¼m (Ā±2.0mils)

Resolution: 1Ī¼m: 0-2mm; 10Ī¼m: 2-13mm (0.1mil: 0-100mils; 1mil: 100-500mils)

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI3

See separate gauges with

F3 PINIPā„¢ Probe

See separate gauges with

F3 PINIPā„¢ Probe

ā—

Separate Model Options

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Separate

A456CFBS

A456CFSS

A456CFTS

ā—

Elcometer 456 Non-Ferrous Separate

A456CNBS

A456CNSS

A456CNTS

ā—

Elcometer 456 Dual FNF Separate

A456CFNFBS

A456CFNFSS

A456CFNFTS

ā—

Probes are supplied separately

* Whichever is the greater
ā—Ā Certificate supplied as standard

Product Features ā– Ā Standard ā–”Ā Optional
Model B Model S Model T
Fast, accurate reading rate; 70+ readings per minute ā–  ā–  ā– 
Repeatable & reproducible measurements ā–  ā–  ā– 
Easy to use menu structure;Ā in 30+ languages ā–  ā–  ā– 
Tough, impact, water & dust resistant;Ā equivalent to IP64 ā–  ā–  ā– 
Bright colour screen;Ā with permanent backlight ā–  ā–  ā– 
Scratch & solvent resistant display;Ā 2.4″ (6cm) TFT ā–  ā–  ā– 
Large positive feedback buttons ā–  ā–  ā– 
USB power supply;Ā via PC ā–  ā–  ā– 
Test certificate ā–  ā–  ā– 
2-year gauge warranty* ā–  ā–  ā– 
Automatic rotating display;Ā 0Ā°, 90Ā°, 180Ā° & 270Ā° ā–  ā–  ā– 
Ambient light sensor;Ā with adjustable auto brightness ā–  ā–  ā– 
Emergency light ā–  ā–  ā– 
Tap awake from sleep ā–  ā–  ā– 
Gauge software updatesĀ¹;Ā via ElcoMasterĀ®Ā software ā–  ā–  ā– 
Data output ā–  ā–  ā– 

USB;Ā to computer

ā–  ā–  ā– 

BluetoothĀ®; to computer, Androidā„¢ & iOSĒ‚Ā devices

ā–  ā– 
On-screen statistics ā–  ā–  ā– 

Number of readings;Ā Ī·

ā–  ā–  ā– 

Mean (average);Ā x

ā–  ā–  ā– 

Standard deviation;Ā Ć³

ā–  ā–  ā– 

Highest reading;Ā Hi

ā–  ā–  ā– 

Lowest reading;Ā Lo

ā–  ā–  ā– 

Coefficient of variation;Ā CV%

ā–  ā–  ā– 

Elcometer index valueĀ²;Ā EIV

ā–  ā–  ā– 

Nominal dry film thickness;Ā NDFT

ā–  ā– 

IMO PSPC;Ā %>NDFT, %>90

ā–  ā– 

High & low limits;Ā definable audible & visual alarms

ā–  ā– 

Number above high limit;

ā–  ā– 

Number below low limit;

ā–  ā– 
Live reading trend graph;Ā in batch mode ā–  ā– 
ElcoMasterĀ®Ā software & USB cable ā–” ā–  ā– 
Replaceable screen protectors ā–” ā–  ā– 
Protective case ā–  ā–  ā– 
Plastic transit case ā–” ā–” ā– 
Integral models; with automatic gauge switch on ā–  ā–  ā– 

Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)Ā³

F, N, FNF F, N, FNF F, N, FNF

Measurement range

0-13mm
0-500mils
Ā 0-1500Ī¼m
0-60mils
Ā 0-1500Ī¼m
0-60mils
Separate models;Ā with automatic probe recognition ā–  ā–  ā– 

Probe type;Ā Ferrous (F), Non-Ferrous (N), Dual (FNF)Ā³

F, N, FNF F, N, FNF F, N, FNF

Measurement range

0-31mm
0-1220mils
0-31mm
0-1220mils
0-31mm
0-1220mils
On-screen calibration instructions;Ā in 30+ languages ā–  ā–  ā– 
Multiple calibration methods ā–  ā–  ā– 

Factory;Ā resets to the factory calibration

ā–  ā–  ā– 

2-point;Ā for smooth and rough surfaces

ā–  ā–  ā– 

1-point;Ā zero calibration

ā–  ā–  ā– 

Zero offset4;Ā for calibration according to ISO19840

ā–  ā– 
Predefined calibration & measurement methods ā–  ā– 

ISO, SSPC PA2, Swedish, Australian

ā–  ā– 
Automatic calibration;Ā for rapid calibration ā–  ā– 
Calibration memory type;Ā gauge (g) or gauge & batch (gb) g gb gb
Number of batches;Ā with unique calibrations 1 2,500
Calibration memories;Ā 3 user-programmable memories ā– 
Measurement outside calibration warning ā– 
Calibration lock;Ā with optional PIN code unlock ā–  ā–  ā– 
Delete last reading ā–  ā–  ā– 
Gauge memory; the number of readings Last 5 1,500 150,000
Individual batch calibrations;Ā sent to PC via ElcoMasterĀ® ā–  ā–  ā– 
Limits;Ā user-definable audible & visual pass/fail warnings ā–  ā–  ā– 

Gauge (g) or gauge & batch specific (gb) limits

g gb
Date and time stamp ā–  ā– 
Batch types;Ā normal, counted average, IMO PSPC ā–  ā– 

Navsea Mode

ā– 
Batch review graph ā– 
Review, clear & delete batches ā–  ā– 
Copy batches and calibration settings ā– 
Alpha-numeric batch names;Ā user-definable on the gauge ā– 
Scan & Auto-Repeat Modes; with Scan probe connected ā– 
Fixed batch size mode;Ā with batch linking ā– 

 

Technical Specifications
Display information 2.4″ (6cm) QVGA colour TFT display, 320 x 240 pixels
Battery type 2 x AA dry cell batteries, rechargeable batteries can also be used
Battery life ~24 hours of continuous use at 1 reading per second5
Gauge dimensions
(h x w x d)
141 x 73 x 37mm (5.55 x 2.87 x 1.46″)
Gauge weight 161g (5.68oz) including supplied batteries
Operating temperature -10 to 50Ā°C (14 to 122Ā°F)
Packing List Elcometer 456 gauge, calibration foils (integrals only), wrist harness, transit case (T), protective case (B, S, T),
1 x screen protectors (S, T), 2 x AA batteries, operating instructions, USB cable (S, T), ElcoMasterĀ®Ā software (S, T)

5Ā Using default settings & lithium batteries, alkaline or rechargeable batteries may differ

STANDARDS:
AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499,Ā ASTM D 1186-B, ASTM D 1400,Ā ASTM D 7091, ASTM E 376, ASTM G 12,Ā BS 3900-C5-6B,Ā BS 3900-C5-6A, BS 5411-11, BS 5411-3,Ā BS 5599,Ā DIN 50981, DIN 50984, ECCA T1,Ā EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2178,Ā ISO 2360,Ā ISO 2808-6A, ISO 2808-6B,Ā ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124,Ā SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32

Standards in grey have been superseded but are still recognised in some industries.

QUICK TIP:

How to take a reading with Elcometer 456:

1. Whilst holding the gauge perpendicular, gently place the probe onto the surface.
Ā· Do not drag the probe across the surface or bang the probe down hard onto the surface as this will damage the probe tip resulting in inaccurate readings.
Ā· >1500Āµmā€™ (ā€™>60milsā€™) indicates a reading over the probe range.

2. For subsequent readings, lift the probe off and then replace it onto the coated surface.
Ā· Do not allow the probe to hover over the surface as this could result in a false reading.

The first reading taken is displayed next to ā€˜1′, the second next to ā€˜2′ etc. When the third reading has been taken, the average (mean, xbar) of the three individual readings displayed is shown (X:).

The average (mean, xbar) reading is cleared when a fourth reading is taken.

By selecting ā€˜Send Individual Readingsā€™ or ā€˜Send Mean (xbar) Readingā€™ via Menu/Bluetooth, the user can choose to transfer the individual readings or just the average (mean, xbar) reading values to Ā® Ā® ElcoMaster or ElcoMaster Mobile Apps – see Section 7 on page 7.

**Note: The Elcometer 456 Separate gauges require the use of a compatible probe – Sold Separately.**

Download Data Sheet
Download Instruction Manual

You may be also interested in:

Elcometer 456 Integral Digital Coating Thickness Gauge

Elcometer 456 with probe is ideal for structures and surfaces assessment.

Ā Also used for aluminum and other non-magnetic metal surfaces. With a reading rate of 140 readings per minute, the Elcometer 456 with probe allows you to inspect more coatings in less time.


ELCOMETER 456 COATING THICKNESS GAUGE MODEL SPECIFICATIONS
Model B FerrousĀ  0-1500Ī¼m (0-60mils) – base model for use with separate probes on ferrous substrates. Add to cart
Model S FerrousĀ  0-1500Ī¼m (0-60mils) – standard model for use with separate probes on ferrous substrates. Add to cart
Model T FerrousĀ  0-1500Ī¼m (0-60mils) – advanced model for use with separate probes on ferrous substrates. Add to cart
Model B Non ferrous 0-1500Ī¼m (0-60mils) – base model for for use with separate probes on non-ferrous substrates. Add to cart
Model S Non ferrous 0-1500Ī¼m (0-60mils) – full model for use with separate probes on non-ferrous substrates. Add to cart
Model T Non ferrous – 0-1500Ī¼m (0-60mils) – advanced model for use with separate probes on non-ferrous substrates. Add to cart
Model B Dual FNF 0-1500Ī¼m (0-60mils) – base model for use with separate probes on both ferrous & non-ferrous substrates. Add to cart
Model S Dual FNF 0-1500Ī¼m (0-60mils) – full model for use with separate probes on both ferrous & non-ferrous substrates Add to cart
Model T Dual FNF 0-1500Ī¼m (0-60mils) advanced model for use with separate probes on both ferrous & non-ferrous substrates. Add to cart

SELECT YOUR MODEL ON TOP OF THE PAGE TO VIEW THE PRICE


Repeatable readings on smooth, rough, thin and curved surfaces

With a wide range of probes available, you obtain great flexibility of access to difficult-to-reach surfaces. All probes are fully interchangeable; while ferrous gauges accept any ferrous probe and non-ferrous gauges accept any non-ferrous probes the dual FNFĀ gauges accept all ferrous, non-ferrous, and dualĀ FNF probes.Ā  Our most advanced model, Model T features memory, alpha-numeric batching, and BluetoothĀ® communication.

Fast Coating Thickness Measurements

The Elcometer 456 Coating Thickness Gauge enhances efficiency by providing 70+ dry film thickness readings per minute (140+ per minute when using a scan probe). The Elcometer 456 mil gauge has multiple calibration memories and alpha numeric batch i

Efficiently scans large surface areas

When using Scan or Auto Repeat Mode, you can get a lot of sampling done quickly, without affecting accuracy. Our highly durable probe cap allows to rapidly scan large surface areas without damaging the probe or the coating.

User-friendly

ā€¢ Large buttons ideal for gloved hands
ā€¢ Multiple languages menus
ā€¢ High contrast colour LCD with auto-rotate
ā€¢ High and low reading limit indicators
ā€¢ Factory calibrated for immediate use
ā€¢ Thickness measurement capability to Ā±1%
ā€¢ Can be used in accordance with National & International Standards
ā€¢ Temperature stable measurements
ā€¢ Increased reading resolution for thin coatings

How reliable is Elcometer 456?

ā€¢ 2-year gauge warranty
ā€¢ Comes with fully traceable test certificates
ā€¢ Batch date and time stamp facility
ā€¢ Rugged casing, suitable for use in harsh environment
ā€¢ Sealed, heavy-duty and impact-resistant
ā€¢ Dust and waterproof equivalent to IP64
ā€¢ Scratch and solvent resistant display
ā€¢ Durable gauge and probe construction
ā€¢ Suitable for harsh environments

Efficient

ā€¢ The fast reading rate of 70+ per minute, 140+ per minute with Scan Probe
ā€¢ Multiple calibration memories.
ā€¢ Alphanumeric batch identification
ā€¢ User-selectable calibration methods

Memory & versatility

ā€¢ Wide range of interchangeable probes
ā€¢ USB and BluetoothĀ® data output to iPhone* or Androidā„¢ devices
ā€¢ Stores up to 150,000 readings in 2,500 batches
ā€¢ Measures up to 31mm (1220mils) of coating on metal substrates

SLASH YOUR COSTSĀ BY GETTING A COMPREHENSIVE KIT FOR YOUR PROJECT

FERROUS / NON-FERROUS METAL INSPECTION KITĀ  |Ā  LARGER PROJECTS INSPECTION KIT 5Ā  |Ā  ALL-INCLUSIVE STRUCTURES ASSEESSMENT KIT 6Ā  | Ā SEE ALL ELCOMETER KITS AVAILABLE FOR SALE – SAVE BIG!

The importance of Coating Thickness Gauge Calibration

Formal quality systems, such as those described in ISO 9001, require coating thickness gauges to be properly controlled, logged, and calibrated. Increasingly, users are specifying that the readings taken by thickness gauges are traceable to National Standards.

In order to test the accuracy of a particular gauge, it is important to have traceable coating thickness standards. Elcometer offers a comprehensive range of certified foils together with zero test plates to ensure the accuracy of the coating thickness gauge. Get the best performance from the Elcometer 456 Coating Thickness Gauge and make the best use of the gaugeā€™s Ā±1% accuracy by calibrating the coating thickness instrument to suit the application. This video will guide you through a range of calibration options for both the integral and the separate models.

Elcometer 456 accuracy and range

Integral Model Options

Scale 1

Range: 0-1500Ī¼m (0-60mils)

Accuracy*: Ā±1-3% or Ā±2.5Ī¼m (Ā±0.1mil)

Resolution: 0.1Ī¼m: 0-100Ī¼m; 1Ī¼m: 100-1500Ī¼m (0.01mil: 0-5mils; 0.1mil: 5-60mils)

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI1

A456CFSI1

A456CFTI1

ā—

Elcometer 456 Non-Ferrous Integral

A456CNBI1

See separate gauges with

N2 PINIPā„¢ Probe

See separate gauges with

N2 PINIPā„¢ Probe

ā—

Elcometer 456 Dual FNF Integral

A456CFNFBI1

A456CFNFSI1

A456CFNFTI1

ā—

Scale 2

Range: 0-5mm (0-200mils)

Accuracy*: Ā±1-3% or Ā±20Ī¼m (Ā±1.0mil)

Resolution: 1Ī¼m: 0-1mm; 10Ī¼m: 1-5mm (0.1mil: 0-50mils; 1mil: 50-200mils)

For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI2

See separate gauges with

F2 PINIPā„¢ Probe

See separate gauges with

F2 PINIPā„¢ Probe

ā—

Scale 3

Range: 0-13mm (0-500mils)

Accuracy*: Ā±1-3% or Ā±50Ī¼m (Ā±2.0mils)

Resolution: 1Ī¼m: 0-2mm; 10Ī¼m: 2-13mm (0.1mil: 0-100mils; 1mil: 100-500mils)

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Integral

A456CFBI3

See separate gauges with

F3 PINIPā„¢ Probe

See separate gauges with

F3 PINIPā„¢ Probe

ā—

Separate Model Options

Model B

Model S

Model T

Certificate

Elcometer 456 Ferrous Separate

A456CFBS

A456CFSS

A456CFTS

ā—

Elcometer 456 Non-Ferrous Separate

A456CNBS

A456CNSS

A456CNTS

ā—

Elcometer 456 Dual FNF Separate

A456CFNFBS

A456CFNFSS

A456CFNFTS

ā—

Probes are supplied separately

* Whichever is the greater
ā—Ā Certificate supplied as standard

Product Features ā– Ā Standard ā–”Ā Optional
Model B Model S Model T
Fast, accurate reading rate; 70+ readings per minute ā–  ā–  ā– 
Repeatable & reproducible measurements ā–  ā–  ā– 
Easy to use menu structure;Ā in 30+ languages ā–  ā–  ā– 
Tough, impact, water & dust resistant;Ā equivalent to IP64 ā–  ā–  ā– 
Bright colour screen;Ā with permanent backlight ā–  ā–  ā– 
Scratch & solvent resistant display;Ā 2.4″ (6cm) TFT ā–  ā–  ā– 
Large positive feedback buttons ā–  ā–  ā– 
USB power supply;Ā via PC ā–  ā–  ā– 
Test certificate ā–  ā–  ā– 
2-year gauge warranty* ā–  ā–  ā– 
Automatic rotating display;Ā 0Ā°, 90Ā°, 180Ā° & 270Ā° ā–  ā–  ā– 
Ambient light sensor;Ā with adjustable auto brightness ā–  ā–  ā– 
Emergency light ā–  ā–  ā– 
Tap awake from sleep ā–  ā–  ā– 
Gauge software updatesĀ¹;Ā via ElcoMasterĀ®Ā software ā–  ā–  ā– 
Data output ā–  ā–  ā– 

USB;Ā to computer

ā–  ā–  ā– 

BluetoothĀ®; to computer, Androidā„¢ & iOSĒ‚Ā devices

ā–  ā– 
On-screen statistics ā–  ā–  ā– 

Number of readings;Ā Ī·

ā–  ā–  ā– 

Mean (average);Ā x

ā–  ā–  ā– 

Standard deviation;Ā Ć³

ā–  ā–  ā– 

Highest reading;Ā Hi

ā–  ā–  ā– 

Lowest reading;Ā Lo

ā–  ā–  ā– 

Coefficient of variation;Ā CV%

ā–  ā–  ā– 

Elcometer index valueĀ²;Ā EIV

ā–  ā–  ā– 

Nominal dry film thickness;Ā NDFT

ā–  ā– 

IMO PSPC;Ā %>NDFT, %>90

ā–  ā– 

High & low limits;Ā definable audible & visual alarms

ā–  ā– 

Number above high limit;

ā–  ā– 

Number below low limit;

ā–  ā– 
Live reading trend graph;Ā in batch mode ā–  ā– 
ElcoMasterĀ®Ā software & USB cable ā–” ā–  ā– 
Replaceable screen protectors ā–” ā–  ā– 
Protective case ā–  ā–  ā– 
Plastic transit case ā–” ā–” ā– 
Integral models; with automatic gauge switch on ā–  ā–  ā– 

Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)Ā³

F, N, FNF F, N, FNF F, N, FNF

Measurement range

0-13mm
0-500mils
Ā 0-1500Ī¼m
0-60mils
Ā 0-1500Ī¼m
0-60mils
Separate models;Ā with automatic probe recognition ā–  ā–  ā– 

Probe type;Ā Ferrous (F), Non-Ferrous (N), Dual (FNF)Ā³

F, N, FNF F, N, FNF F, N, FNF

Measurement range

0-31mm
0-1220mils
0-31mm
0-1220mils
0-31mm
0-1220mils
On-screen calibration instructions;Ā in 30+ languages ā–  ā–  ā– 
Multiple calibration methods ā–  ā–  ā– 

Factory;Ā resets to the factory calibration

ā–  ā–  ā– 

2-point;Ā for smooth and rough surfaces

ā–  ā–  ā– 

1-point;Ā zero calibration

ā–  ā–  ā– 

Zero offset4;Ā for calibration according to ISO19840

ā–  ā– 
Predefined calibration & measurement methods ā–  ā– 

ISO, SSPC PA2, Swedish, Australian

ā–  ā– 
Automatic calibration;Ā for rapid calibration ā–  ā– 
Calibration memory type;Ā gauge (g) or gauge & batch (gb) g gb gb
Number of batches;Ā with unique calibrations 1 2,500
Calibration memories;Ā 3 user-programmable memories ā– 
Measurement outside calibration warning ā– 
Calibration lock;Ā with optional PIN code unlock ā–  ā–  ā– 
Delete last reading ā–  ā–  ā– 
Gauge memory; the number of readings Last 5 1,500 150,000
Individual batch calibrations;Ā sent to PC via ElcoMasterĀ® ā–  ā–  ā– 
Limits;Ā user-definable audible & visual pass/fail warnings ā–  ā–  ā– 

Gauge (g) or gauge & batch specific (gb) limits

g gb
Date and time stamp ā–  ā– 
Batch types;Ā normal, counted average, IMO PSPC ā–  ā– 

Navsea Mode

ā– 
Batch review graph ā– 
Review, clear & delete batches ā–  ā– 
Copy batches and calibration settings ā– 
Alpha-numeric batch names;Ā user-definable on the gauge ā– 
Scan & Auto-Repeat Modes; with Scan probe connected ā– 
Fixed batch size mode;Ā with batch linking ā– 

 

Technical Specifications
Display information 2.4″ (6cm) QVGA colour TFT display, 320 x 240 pixels
Battery type 2 x AA dry cell batteries, rechargeable batteries can also be used
Battery life ~24 hours of continuous use at 1 reading per second5
Gauge dimensions
(h x w x d)
141 x 73 x 37mm (5.55 x 2.87 x 1.46″)
Gauge weight 161g (5.68oz) including supplied batteries
Operating temperature -10 to 50Ā°C (14 to 122Ā°F)
Packing List Elcometer 456 gauge, calibration foils (integrals only), wrist harness, transit case (T), protective case (B, S, T),
1 x screen protectors (S, T), 2 x AA batteries, operating instructions, USB cable (S, T), ElcoMasterĀ®Ā software (S, T)

5Ā Using default settings & lithium batteries, alkaline or rechargeable batteries may differ

STANDARDS:
AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499,Ā ASTM D 1186-B, ASTM D 1400,Ā ASTM D 7091, ASTM E 376, ASTM G 12,Ā BS 3900-C5-6B,Ā BS 3900-C5-6A, BS 5411-11, BS 5411-3,Ā BS 5599,Ā DIN 50981, DIN 50984, ECCA T1,Ā EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2178,Ā ISO 2360,Ā ISO 2808-6A, ISO 2808-6B,Ā ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124,Ā SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32

Standards in grey have been superseded but are still recognised in some industries.

QUICK TIP:

How to take a reading with Elcometer 456:

1. Whilst holding the gauge perpendicular, gently place the probe onto the surface.
Ā· Do not drag the probe across the surface or bang the probe down hard onto the surface as this will damage the probe tip resulting in inaccurate readings.
Ā· >1500Āµmā€™ (ā€™>60milsā€™) indicates a reading over the probe range.

2. For subsequent readings, lift the probe off and then replace it onto the coated surface.
Ā· Do not allow the probe to hover over the surface as this could result in a false reading.

The first reading taken is displayed next to ā€˜1′, the second next to ā€˜2′ etc. When the third reading has been taken, the average (mean, xbar) of the three individual readings displayed is shown (X:).

The average (mean, xbar) reading is cleared when a fourth reading is taken.

By selecting ā€˜Send Individual Readingsā€™ or ā€˜Send Mean (xbar) Readingā€™ via Menu/Bluetooth, the user can choose to transfer the individual readings or just the average (mean, xbar) reading values to Ā® Ā® ElcoMaster or ElcoMaster Mobile Apps – see Section 7 on page 7.

**Note: The Elcometer 456 Separate gauges require the use of a compatible probe – Sold Separately.**

Download Data Sheet
Download Instruction Manual

You may be also interested in:

Elcometer 456 Integral Digital Coating Thickness Gauge