The new Elcometer 456 with probe variety available (separate model gauge) sets new standards for measuring the thickness of a coating.
Ideal for structures and surfaces assessment. A great stainless steel gauge, also used for aluminium and other non-magnetic metal surfaces. With a reading rate of 140 readings per minute, the Elcometer 456 with Probe allows you to inspect more coatings in less time. Featuring a highly durable probe cap, the Elcometer 456 Coating Thickness Gauge Scan Probe is a revolutionary design that allows users to take individual dry film thickness readings or rapidly scan large surface areas – without damaging the probe or the coating.
Separate models, with their wide range of probes, provide great measurement flexibility. All probes are fully interchangeable; whilst ferrous gauges accept any ferrous probe and non-ferrous gauges accept any non-ferrous probes the dual FNF gauges accept all ferrous, non-ferrous, and dual FNF probes. Beginning with Model E and ending with Model T, the Elcometer 456 is available in four different models. Our most advanced model, Model T features memory, alpha-numeric batching, and Bluetooth® communication.
ELCOMETER 456 COATING THICKNESS GAUGE MODEL SPECIFICATIONS
Model B Ferrous 0-1500μm (0-60mils) – base model for use with separate probes on ferrous substrates.
Model S Ferrous 0-1500μm (0-60mils) – standard model for use with separate probes on ferrous substrates.
Model T Ferrous 0-1500μm (0-60mils) – advanced model for use with separate probes on ferrous substrates.
Model B Non ferrous 0-1500μm (0-60mils) – base model for for use with separate probes on non-ferrous substrates.
Model S Non ferrous 0-1500μm (0-60mils) – full model for use with separate probes on non-ferrous substrates.
Model T Non ferrous – 0-1500μm (0-60mils) advanced model for use with separate probes on non-ferrous substrates.
Model B Dual FNF 0-1500μm (0-60mils) – base model for use with separate probes on both ferrous & non-ferrous substrates.
Model S Dual FNF 0-1500μm (0-60mils) – full model for use with separate probes on both ferrous & non-ferrous substrates
Model T Dual FNF 0-1500μm (0-60mils) – advanced model for use with separate probes on both ferrous & non-ferrous substrates.
SELECT YOUR MODEL ON TOP OF THE PAGE TO VIEW THE PRICE
**Note: The Elcometer 456 Separate gauges require the use of a compatible probe – Sold Separately.**
When used in conjunction with the Elcometer 456 Coating Thickness Gauge Scan or Auto Repeat Mode, the Scan Probe enables users to significantly reduce dry film thickness inspection times without affecting accuracy.
User friendly
- Large buttons ideal for gloved hands
- Easy to use menus in multiple languages
- High contrast colour LCD with auto-rotate
- High and low reading limit indicators
- Factory calibrated for immediate use
Elcometer 456 is amazingly accurate
- Thickness measurement capability to ±1% Can be used in accordance with National & International Standards
- Temperature stable measurements
- Increased reading resolution for thin coatings
- Measures accurately on smooth, rough, thin and curved surfaces e456
Elcometer 456 is extremely reliable
- Repeatable and reproducible 2-year gauge warranty
- Supplied with fully traceable test certificates
- Batch date and time stamp facility
Rugged casing, suitable for use in harsh environment
- Sealed, heavy-duty and impact-resistant
- Dust and waterproof equivalent to IP64
- Scratch and solvent resistant display
- Durable gauge and probe construction
- Suitable for use in harsh environments
Efficient
- The fast reading rate of 70+ per minute, 140+ per minute with Scan Probe
- Multiple calibration memories. Alphanumeric batch identification
- User-selectable calibration methods
Powerful & versatile
- Wide range of interchangeable probes
- USB and Bluetooth® data output to iPhone* or Android™ devices
- Stores up to 150,000 readings in 2,500 batches
- Measures up to 31mm (1220mils) of coating on metal substrates
Free shipping makes us a great place to buy Elcometer 456!
SLASH YOUR COSTS BY GETTING A COMPREHENSIVE KIT FOR YOUR PROJECT
FERROUS / NON-FERROUS METAL INSPECTION KIT | LARGER PROJECTS INSPECTION KIT 5 | ALL-INCLUSIVE STRUCTURES ASSEESSMET KIT 6 | SEE ALL ELCOMETER KITS AVAILABLE FOR SALE – SAVE BIG!
The importance of Coating Thickness Gauge Calibration
Formal quality systems, such as those described in ISO 9001, require coating thickness gauges to be properly controlled, logged, and calibrated. Increasingly, users are specifying that the readings taken by thickness gauges are traceable to National Standards.
In order to test the accuracy of a particular gauge, it is important to have traceable coating thickness standards. Elcometer offers a comprehensive range of certified foils together with zero test plates to ensure the accuracy of the coating thickness gauge. Get the best performance from the Elcometer 456 Coating Thickness Gauge and make the best use of the gauge’s ±1% accuracy by calibrating the coating thickness instrument to suit the application. This video will guide you through a range of calibration options for both the integral and the separate models.
Elcometer 456 accuracy and range
Integral Model Options |
|||||||||
Scale 1 |
Range: 0-1500μm (0-60mils) |
Accuracy*: ±1-3% or ±2.5μm (±0.1mil) |
|||||||
Resolution: 0.1μm: 0-100μm; 1μm: 100-1500μm (0.01mil: 0-5mils; 0.1mil: 5-60mils) |
|||||||||
Model B |
Model S |
Model T |
Certificate | ||||||
Elcometer 456 Ferrous Integral |
A456CFBI1 |
A456CFSI1 |
A456CFTI1 |
● |
|||||
Elcometer 456 Non-Ferrous Integral |
A456CNBI1 |
See separate gauges with N2 PINIP™ Probe |
See separate gauges with N2 PINIP™ Probe |
● |
|||||
Elcometer 456 Dual FNF Integral |
A456CFNFBI1 |
A456CFNFSI1 |
A456CFNFTI1 |
● |
|||||
Scale 2 |
Range: 0-5mm (0-200mils) |
Accuracy*: ±1-3% or ±20μm (±1.0mil) |
|||||||
Resolution: 1μm: 0-1mm; 10μm: 1-5mm (0.1mil: 0-50mils; 1mil: 50-200mils) |
|||||||||
For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance |
|||||||||
Model B |
Model S |
Model T |
Certificate |
||||||
Elcometer 456 Ferrous Integral |
A456CFBI2 |
See separate gauges with F2 PINIP™ Probe |
See separate gauges with F2 PINIP™ Probe |
● |
|||||
Scale 3 |
Range: 0-13mm (0-500mils) |
Accuracy*: ±1-3% or ±50μm (±2.0mils) |
|||||||
Resolution: 1μm: 0-2mm; 10μm: 2-13mm (0.1mil: 0-100mils; 1mil: 100-500mils) |
|||||||||
Model B |
Model S |
Model T |
Certificate |
||||||
Elcometer 456 Ferrous Integral |
A456CFBI3 |
See separate gauges with F3 PINIP™ Probe |
See separate gauges with F3 PINIP™ Probe |
● |
|||||
Separate Model Options |
|||||||||
Model B |
Model S |
Model T |
Certificate |
||||||
Elcometer 456 Ferrous Separate |
A456CFBS |
A456CFSS |
A456CFTS |
● |
|||||
Elcometer 456 Non-Ferrous Separate |
A456CNBS |
A456CNSS |
A456CNTS |
● |
|||||
Elcometer 456 Dual FNF Separate |
A456CFNFBS |
A456CFNFSS |
A456CFNFTS |
● |
|||||
Probes are supplied separately |
* Whichever is the greater
● Certificate supplied as standard
Product Features | ■ Standard | □ Optional | |
Model B | Model S | Model T | |
Fast, accurate reading rate; 70+ readings per minute | ■ | ■ | ■ |
Repeatable & reproducible measurements | ■ | ■ | ■ |
Easy to use menu structure; in 30+ languages | ■ | ■ | ■ |
Tough, impact, water & dust resistant; equivalent to IP64 | ■ | ■ | ■ |
Bright colour screen; with permanent backlight | ■ | ■ | ■ |
Scratch & solvent resistant display; 2.4″ (6cm) TFT | ■ | ■ | ■ |
Large positive feedback buttons | ■ | ■ | ■ |
USB power supply; via PC | ■ | ■ | ■ |
Test certificate | ■ | ■ | ■ |
2-year gauge warranty* | ■ | ■ | ■ |
Automatic rotating display; 0°, 90°, 180° & 270° | ■ | ■ | ■ |
Ambient light sensor; with adjustable auto brightness | ■ | ■ | ■ |
Emergency light | ■ | ■ | ■ |
Tap awake from sleep | ■ | ■ | ■ |
Gauge software updates¹; via ElcoMaster® software | ■ | ■ | ■ |
Data output | ■ | ■ | ■ |
USB; to computer |
■ | ■ | ■ |
Bluetooth®; to computer, Android™ & iOSǂ devices |
■ | ■ | |
On-screen statistics | ■ | ■ | ■ |
Number of readings; η |
■ | ■ | ■ |
Mean (average); x |
■ | ■ | ■ |
Standard deviation; ó |
■ | ■ | ■ |
Highest reading; Hi |
■ | ■ | ■ |
Lowest reading; Lo |
■ | ■ | ■ |
Coefficient of variation; CV% |
■ | ■ | ■ |
Elcometer index value²; EIV |
■ | ■ | ■ |
Nominal dry film thickness; NDFT |
■ | ■ | |
IMO PSPC; %>NDFT, %>90 |
■ | ■ | |
High & low limits; definable audible & visual alarms |
■ | ■ | |
Number above high limit; |
■ | ■ | |
Number below low limit; |
■ | ■ | |
Live reading trend graph; in batch mode | ■ | ■ | |
ElcoMaster® software & USB cable | □ | ■ | ■ |
Replaceable screen protectors | □ | ■ | ■ |
Protective case | ■ | ■ | ■ |
Plastic transit case | □ | □ | ■ |
Integral models; with automatic gauge switch on | ■ | ■ | ■ |
Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³ |
F, N, FNF | F, N, FNF | F, N, FNF |
Measurement range |
0-13mm 0-500mils |
0-1500μm 0-60mils |
0-1500μm 0-60mils |
Separate models; with automatic probe recognition | ■ | ■ | ■ |
Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³ |
F, N, FNF | F, N, FNF | F, N, FNF |
Measurement range |
0-31mm 0-1220mils |
0-31mm 0-1220mils |
0-31mm 0-1220mils |
On-screen calibration instructions; in 30+ languages | ■ | ■ | ■ |
Multiple calibration methods | ■ | ■ | ■ |
Factory; resets to the factory calibration |
■ | ■ | ■ |
2-point; for smooth and rough surfaces |
■ | ■ | ■ |
1-point; zero calibration |
■ | ■ | ■ |
Zero offset4; for calibration according to ISO19840 |
■ | ■ | |
Predefined calibration & measurement methods | ■ | ■ | |
ISO, SSPC PA2, Swedish, Australian |
■ | ■ | |
Automatic calibration; for rapid calibration | ■ | ■ | |
Calibration memory type; gauge (g) or gauge & batch (gb) | g | gb | gb |
Number of batches; with unique calibrations | 1 | 2,500 | |
Calibration memories; 3 user-programmable memories | ■ | ||
Measurement outside calibration warning | ■ | ||
Calibration lock; with optional PIN code unlock | ■ | ■ | ■ |
Delete last reading | ■ | ■ | ■ |
Gauge memory; the number of readings | Last 5 | 1,500 | 150,000 |
Individual batch calibrations; sent to PC via ElcoMaster® | ■ | ■ | ■ |
Limits; user-definable audible & visual pass/fail warnings | ■ | ■ | ■ |
Gauge (g) or gauge & batch specific (gb) limits |
g | gb | |
Date and time stamp | ■ | ■ | |
Batch types; normal, counted average, IMO PSPC | ■ | ■ | |
Navsea Mode |
■ | ||
Batch review graph | ■ | ||
Review, clear & delete batches | ■ | ■ | |
Copy batches and calibration settings | ■ | ||
Alpha-numeric batch names; user-definable on the gauge | ■ | ||
Scan & Auto-Repeat Modes; with Scan probe connected | ■ | ||
Fixed batch size mode; with batch linking | ■ |
Technical Specifications | |
Display information | 2.4″ (6cm) QVGA colour TFT display, 320 x 240 pixels |
Battery type | 2 x AA dry cell batteries, rechargeable batteries can also be used |
Battery life | ~24 hours of continuous use at 1 reading per second5 |
Gauge dimensions (h x w x d) |
141 x 73 x 37mm (5.55 x 2.87 x 1.46″) |
Gauge weight | 161g (5.68oz) including supplied batteries |
Operating temperature | -10 to 50°C (14 to 122°F) |
Packing List | Elcometer 456 gauge, calibration foils (integrals only), wrist harness, transit case (T), protective case (B, S, T), 1 x screen protectors (S, T), 2 x AA batteries, operating instructions, USB cable (S, T), ElcoMaster® software (S, T) |
5 Using default settings & lithium batteries, alkaline or rechargeable batteries may differ
STANDARDS:
AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091, ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984, ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2178, ISO 2360, ISO 2808-6A, ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32
Standards in grey have been superseded but are still recognised in some industries.
QUICK TIP:
How to take a reading with Elcometer 456:
1. Whilst holding the gauge perpendicular, gently place the probe onto the surface.
· Do not drag the probe across the surface or bang the probe down hard onto the surface as this will damage the probe tip resulting in inaccurate readings.
· >1500µm’ (’>60mils’) indicates a reading over the probe range.
2. For subsequent readings, lift the probe off and then replace it onto the coated surface.
· Do not allow the probe to hover over the surface as this could result in a false reading.
The first reading taken is displayed next to ‘1′, the second next to ‘2′ etc. When the third reading has been taken, the average (mean, xbar) of the three individual readings displayed is shown (X:).
The average (mean, xbar) reading is cleared when a fourth reading is taken.
By selecting ‘Send Individual Readings’ or ‘Send Mean (xbar) Reading’ via Menu/Bluetooth, the user can choose to transfer the individual readings or just the average (mean, xbar) reading values to ® ® ElcoMaster or ElcoMaster Mobile Apps – see Section 7 on page 7.
Download Data Sheet
Download Instruction Manual
You may be also interested in:
The new Elcometer 456 with probe variety available (separate model gauge) sets new standards for measuring the thickness of a coating.
Ideal for structures and surfaces assessment. A great stainless steel gauge, also used for aluminium and other non-magnetic metal surfaces. With a reading rate of 140 readings per minute, the Elcometer 456 with Probe allows you to inspect more coatings in less time. Featuring a highly durable probe cap, the Elcometer 456 Coating Thickness Gauge Scan Probe is a revolutionary design that allows users to take individual dry film thickness readings or rapidly scan large surface areas – without damaging the probe or the coating.
Separate models, with their wide range of probes, provide great measurement flexibility. All probes are fully interchangeable; whilst ferrous gauges accept any ferrous probe and non-ferrous gauges accept any non-ferrous probes the dual FNF gauges accept all ferrous, non-ferrous, and dual FNF probes. Beginning with Model E and ending with Model T, the Elcometer 456 is available in four different models. Our most advanced model, Model T features memory, alpha-numeric batching, and Bluetooth® communication.
ELCOMETER 456 COATING THICKNESS GAUGE MODEL SPECIFICATIONS
Model B Ferrous 0-1500μm (0-60mils) – base model for use with separate probes on ferrous substrates.
Model S Ferrous 0-1500μm (0-60mils) – standard model for use with separate probes on ferrous substrates.
Model T Ferrous 0-1500μm (0-60mils) – advanced model for use with separate probes on ferrous substrates.
Model B Non ferrous 0-1500μm (0-60mils) – base model for for use with separate probes on non-ferrous substrates.
Model S Non ferrous 0-1500μm (0-60mils) – full model for use with separate probes on non-ferrous substrates.
Model T Non ferrous – 0-1500μm (0-60mils) advanced model for use with separate probes on non-ferrous substrates.
Model B Dual FNF 0-1500μm (0-60mils) – base model for use with separate probes on both ferrous & non-ferrous substrates.
Model S Dual FNF 0-1500μm (0-60mils) – full model for use with separate probes on both ferrous & non-ferrous substrates
Model T Dual FNF 0-1500μm (0-60mils) – advanced model for use with separate probes on both ferrous & non-ferrous substrates.
SELECT YOUR MODEL ON TOP OF THE PAGE TO VIEW THE PRICE
**Note: The Elcometer 456 Separate gauges require the use of a compatible probe – Sold Separately.**
When used in conjunction with the Elcometer 456 Coating Thickness Gauge Scan or Auto Repeat Mode, the Scan Probe enables users to significantly reduce dry film thickness inspection times without affecting accuracy.
User friendly
- Large buttons ideal for gloved hands
- Easy to use menus in multiple languages
- High contrast colour LCD with auto-rotate
- High and low reading limit indicators
- Factory calibrated for immediate use
Elcometer 456 is amazingly accurate
- Thickness measurement capability to ±1% Can be used in accordance with National & International Standards
- Temperature stable measurements
- Increased reading resolution for thin coatings
- Measures accurately on smooth, rough, thin and curved surfaces e456
Elcometer 456 is extremely reliable
- Repeatable and reproducible 2-year gauge warranty
- Supplied with fully traceable test certificates
- Batch date and time stamp facility
Rugged casing, suitable for use in harsh environment
- Sealed, heavy-duty and impact-resistant
- Dust and waterproof equivalent to IP64
- Scratch and solvent resistant display
- Durable gauge and probe construction
- Suitable for use in harsh environments
Efficient
- The fast reading rate of 70+ per minute, 140+ per minute with Scan Probe
- Multiple calibration memories. Alphanumeric batch identification
- User-selectable calibration methods
Powerful & versatile
- Wide range of interchangeable probes
- USB and Bluetooth® data output to iPhone* or Android™ devices
- Stores up to 150,000 readings in 2,500 batches
- Measures up to 31mm (1220mils) of coating on metal substrates
Free shipping makes us a great place to buy Elcometer 456!
SLASH YOUR COSTS BY GETTING A COMPREHENSIVE KIT FOR YOUR PROJECT
FERROUS / NON-FERROUS METAL INSPECTION KIT | LARGER PROJECTS INSPECTION KIT 5 | ALL-INCLUSIVE STRUCTURES ASSEESSMET KIT 6 | SEE ALL ELCOMETER KITS AVAILABLE FOR SALE – SAVE BIG!
The importance of Coating Thickness Gauge Calibration
Formal quality systems, such as those described in ISO 9001, require coating thickness gauges to be properly controlled, logged, and calibrated. Increasingly, users are specifying that the readings taken by thickness gauges are traceable to National Standards.
In order to test the accuracy of a particular gauge, it is important to have traceable coating thickness standards. Elcometer offers a comprehensive range of certified foils together with zero test plates to ensure the accuracy of the coating thickness gauge. Get the best performance from the Elcometer 456 Coating Thickness Gauge and make the best use of the gauge’s ±1% accuracy by calibrating the coating thickness instrument to suit the application. This video will guide you through a range of calibration options for both the integral and the separate models.
Elcometer 456 accuracy and range
Integral Model Options |
|||||||||
Scale 1 |
Range: 0-1500μm (0-60mils) |
Accuracy*: ±1-3% or ±2.5μm (±0.1mil) |
|||||||
Resolution: 0.1μm: 0-100μm; 1μm: 100-1500μm (0.01mil: 0-5mils; 0.1mil: 5-60mils) |
|||||||||
Model B |
Model S |
Model T |
Certificate | ||||||
Elcometer 456 Ferrous Integral |
A456CFBI1 |
A456CFSI1 |
A456CFTI1 |
● |
|||||
Elcometer 456 Non-Ferrous Integral |
A456CNBI1 |
See separate gauges with N2 PINIP™ Probe |
See separate gauges with N2 PINIP™ Probe |
● |
|||||
Elcometer 456 Dual FNF Integral |
A456CFNFBI1 |
A456CFNFSI1 |
A456CFNFTI1 |
● |
|||||
Scale 2 |
Range: 0-5mm (0-200mils) |
Accuracy*: ±1-3% or ±20μm (±1.0mil) |
|||||||
Resolution: 1μm: 0-1mm; 10μm: 1-5mm (0.1mil: 0-50mils; 1mil: 50-200mils) |
|||||||||
For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance |
|||||||||
Model B |
Model S |
Model T |
Certificate |
||||||
Elcometer 456 Ferrous Integral |
A456CFBI2 |
See separate gauges with F2 PINIP™ Probe |
See separate gauges with F2 PINIP™ Probe |
● |
|||||
Scale 3 |
Range: 0-13mm (0-500mils) |
Accuracy*: ±1-3% or ±50μm (±2.0mils) |
|||||||
Resolution: 1μm: 0-2mm; 10μm: 2-13mm (0.1mil: 0-100mils; 1mil: 100-500mils) |
|||||||||
Model B |
Model S |
Model T |
Certificate |
||||||
Elcometer 456 Ferrous Integral |
A456CFBI3 |
See separate gauges with F3 PINIP™ Probe |
See separate gauges with F3 PINIP™ Probe |
● |
|||||
Separate Model Options |
|||||||||
Model B |
Model S |
Model T |
Certificate |
||||||
Elcometer 456 Ferrous Separate |
A456CFBS |
A456CFSS |
A456CFTS |
● |
|||||
Elcometer 456 Non-Ferrous Separate |
A456CNBS |
A456CNSS |
A456CNTS |
● |
|||||
Elcometer 456 Dual FNF Separate |
A456CFNFBS |
A456CFNFSS |
A456CFNFTS |
● |
|||||
Probes are supplied separately |
* Whichever is the greater
● Certificate supplied as standard
Product Features | ■ Standard | □ Optional | |
Model B | Model S | Model T | |
Fast, accurate reading rate; 70+ readings per minute | ■ | ■ | ■ |
Repeatable & reproducible measurements | ■ | ■ | ■ |
Easy to use menu structure; in 30+ languages | ■ | ■ | ■ |
Tough, impact, water & dust resistant; equivalent to IP64 | ■ | ■ | ■ |
Bright colour screen; with permanent backlight | ■ | ■ | ■ |
Scratch & solvent resistant display; 2.4″ (6cm) TFT | ■ | ■ | ■ |
Large positive feedback buttons | ■ | ■ | ■ |
USB power supply; via PC | ■ | ■ | ■ |
Test certificate | ■ | ■ | ■ |
2-year gauge warranty* | ■ | ■ | ■ |
Automatic rotating display; 0°, 90°, 180° & 270° | ■ | ■ | ■ |
Ambient light sensor; with adjustable auto brightness | ■ | ■ | ■ |
Emergency light | ■ | ■ | ■ |
Tap awake from sleep | ■ | ■ | ■ |
Gauge software updates¹; via ElcoMaster® software | ■ | ■ | ■ |
Data output | ■ | ■ | ■ |
USB; to computer |
■ | ■ | ■ |
Bluetooth®; to computer, Android™ & iOSǂ devices |
■ | ■ | |
On-screen statistics | ■ | ■ | ■ |
Number of readings; η |
■ | ■ | ■ |
Mean (average); x |
■ | ■ | ■ |
Standard deviation; ó |
■ | ■ | ■ |
Highest reading; Hi |
■ | ■ | ■ |
Lowest reading; Lo |
■ | ■ | ■ |
Coefficient of variation; CV% |
■ | ■ | ■ |
Elcometer index value²; EIV |
■ | ■ | ■ |
Nominal dry film thickness; NDFT |
■ | ■ | |
IMO PSPC; %>NDFT, %>90 |
■ | ■ | |
High & low limits; definable audible & visual alarms |
■ | ■ | |
Number above high limit; |
■ | ■ | |
Number below low limit; |
■ | ■ | |
Live reading trend graph; in batch mode | ■ | ■ | |
ElcoMaster® software & USB cable | □ | ■ | ■ |
Replaceable screen protectors | □ | ■ | ■ |
Protective case | ■ | ■ | ■ |
Plastic transit case | □ | □ | ■ |
Integral models; with automatic gauge switch on | ■ | ■ | ■ |
Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³ |
F, N, FNF | F, N, FNF | F, N, FNF |
Measurement range |
0-13mm 0-500mils |
0-1500μm 0-60mils |
0-1500μm 0-60mils |
Separate models; with automatic probe recognition | ■ | ■ | ■ |
Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³ |
F, N, FNF | F, N, FNF | F, N, FNF |
Measurement range |
0-31mm 0-1220mils |
0-31mm 0-1220mils |
0-31mm 0-1220mils |
On-screen calibration instructions; in 30+ languages | ■ | ■ | ■ |
Multiple calibration methods | ■ | ■ | ■ |
Factory; resets to the factory calibration |
■ | ■ | ■ |
2-point; for smooth and rough surfaces |
■ | ■ | ■ |
1-point; zero calibration |
■ | ■ | ■ |
Zero offset4; for calibration according to ISO19840 |
■ | ■ | |
Predefined calibration & measurement methods | ■ | ■ | |
ISO, SSPC PA2, Swedish, Australian |
■ | ■ | |
Automatic calibration; for rapid calibration | ■ | ■ | |
Calibration memory type; gauge (g) or gauge & batch (gb) | g | gb | gb |
Number of batches; with unique calibrations | 1 | 2,500 | |
Calibration memories; 3 user-programmable memories | ■ | ||
Measurement outside calibration warning | ■ | ||
Calibration lock; with optional PIN code unlock | ■ | ■ | ■ |
Delete last reading | ■ | ■ | ■ |
Gauge memory; the number of readings | Last 5 | 1,500 | 150,000 |
Individual batch calibrations; sent to PC via ElcoMaster® | ■ | ■ | ■ |
Limits; user-definable audible & visual pass/fail warnings | ■ | ■ | ■ |
Gauge (g) or gauge & batch specific (gb) limits |
g | gb | |
Date and time stamp | ■ | ■ | |
Batch types; normal, counted average, IMO PSPC | ■ | ■ | |
Navsea Mode |
■ | ||
Batch review graph | ■ | ||
Review, clear & delete batches | ■ | ■ | |
Copy batches and calibration settings | ■ | ||
Alpha-numeric batch names; user-definable on the gauge | ■ | ||
Scan & Auto-Repeat Modes; with Scan probe connected | ■ | ||
Fixed batch size mode; with batch linking | ■ |
Technical Specifications | |
Display information | 2.4″ (6cm) QVGA colour TFT display, 320 x 240 pixels |
Battery type | 2 x AA dry cell batteries, rechargeable batteries can also be used |
Battery life | ~24 hours of continuous use at 1 reading per second5 |
Gauge dimensions (h x w x d) |
141 x 73 x 37mm (5.55 x 2.87 x 1.46″) |
Gauge weight | 161g (5.68oz) including supplied batteries |
Operating temperature | -10 to 50°C (14 to 122°F) |
Packing List | Elcometer 456 gauge, calibration foils (integrals only), wrist harness, transit case (T), protective case (B, S, T), 1 x screen protectors (S, T), 2 x AA batteries, operating instructions, USB cable (S, T), ElcoMaster® software (S, T) |
5 Using default settings & lithium batteries, alkaline or rechargeable batteries may differ
STANDARDS:
AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091, ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984, ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2178, ISO 2360, ISO 2808-6A, ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32
Standards in grey have been superseded but are still recognised in some industries.
QUICK TIP:
How to take a reading with Elcometer 456:
1. Whilst holding the gauge perpendicular, gently place the probe onto the surface.
· Do not drag the probe across the surface or bang the probe down hard onto the surface as this will damage the probe tip resulting in inaccurate readings.
· >1500µm’ (’>60mils’) indicates a reading over the probe range.
2. For subsequent readings, lift the probe off and then replace it onto the coated surface.
· Do not allow the probe to hover over the surface as this could result in a false reading.
The first reading taken is displayed next to ‘1′, the second next to ‘2′ etc. When the third reading has been taken, the average (mean, xbar) of the three individual readings displayed is shown (X:).
The average (mean, xbar) reading is cleared when a fourth reading is taken.
By selecting ‘Send Individual Readings’ or ‘Send Mean (xbar) Reading’ via Menu/Bluetooth, the user can choose to transfer the individual readings or just the average (mean, xbar) reading values to ® ® ElcoMaster or ElcoMaster Mobile Apps – see Section 7 on page 7.
Download Data Sheet
Download Instruction Manual