This thickness transducer is designed for applications on glass, aluminium, and titanium applications
Works seamlessly with the ElcometerNDT MTG4, MTG6DL, and MTG8DL model instruments. Also works with Elcometer 304CDL.
Dual & Single Element Transducers |
||||||||||||||||||||||
Connector Type | Suitable for Measuring | Suitable For | ||||||||||||||||||||
Part Number
|
Probe Diameter
|
Probe Configuration
|
Damping
|
ThruPaintTM
|
Potted Right Angle
|
Microdot
|
Cast Iron
|
Plastics
|
Thin Plastics
|
Fiberglass
|
Thin Fiberglass
|
Steel
|
Glass
|
Aluminium
|
Titanium
|
MTG2
|
MTG4
|
MTG6
|
MTG8
|
PTG6
|
PTG8
|
Calibration Certificate
|
1.00 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC1M00EP-2 | 1/2″ | Right Angle | S | • | • | • | • | • | • | • | • | • | ||||||||||
2.25 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC2M25CP-2 | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | • | ||||||||||
TXC2M25EP-2 | 1/2″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
3.50 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC3M50EP-1 | 1/2″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | • | ||||||||
5.00 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC5M00BP-4 | 3/16″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | |||||||||
TXC5M00CP-4 | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | • | ||||||||||
TXC5M00BP-6 | 1/4″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | |||||||||
TXC5M00CP-8 | 1/4″ | High Temp | HD | • | • | • | • | • | • | • | • | • | ||||||||||
TXC5M00EP-3 | 1/2″ | Right Angle | S | • | • | • | • | • | • | • | • | • | ||||||||||
TXC5M00EP-4 | 1/2″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | |||||||||
7.50 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC7M50BP-3 | 3/16″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | • | ||||||||
TXC7M50CP-4 | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | • | • | |||||||||
TXC7M50CP-5 | 1/4″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | • | ||||||||
10.0 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC10M0BP-1 | 3/16″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
TXC10M0CP-4 | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
15.0 MHz Single Element Transducer |
||||||||||||||||||||||
TXC15M0CM | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
20.0 MHz Single Element Transducer |
||||||||||||||||||||||
TXC20M0CM | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
Delay Lines |
||||||||||||||||||||||
Each gauge is supplied with 9mm and 12mm acrylic delay lines suitable for measuring on steel, aluminum and titanium. If measuring on thin plastics using Plastic Mode (PLAS), a graphite delay line must be used. These are available to purchase as optional accessories. |
||||||||||||||||||||||
Part Number | Description | |||||||||||||||||||||
T92016528 | Acrylic Delay Line; 1/4 Dia x 9mm | |||||||||||||||||||||
T92016529 | Acrylic Delay Line; 1/4 Dia x 12mm | |||||||||||||||||||||
T92023853-4 | Graphite Delay Line; 1/4 Dia x 3/16″ | |||||||||||||||||||||
All transducers are supplied with a calibration certificate HD—Highly damped Transducer CT—Damped Coating Thickness Transducer S—–Standard undamped Transducer |
This thickness transducer is designed for applications on glass, aluminium, and titanium applications
Works seamlessly with the ElcometerNDT MTG4, MTG6DL, and MTG8DL model instruments. Also works with Elcometer 304CDL.
Dual & Single Element Transducers |
||||||||||||||||||||||
Connector Type | Suitable for Measuring | Suitable For | ||||||||||||||||||||
Part Number
|
Probe Diameter
|
Probe Configuration
|
Damping
|
ThruPaintTM
|
Potted Right Angle
|
Microdot
|
Cast Iron
|
Plastics
|
Thin Plastics
|
Fiberglass
|
Thin Fiberglass
|
Steel
|
Glass
|
Aluminium
|
Titanium
|
MTG2
|
MTG4
|
MTG6
|
MTG8
|
PTG6
|
PTG8
|
Calibration Certificate
|
1.00 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC1M00EP-2 | 1/2″ | Right Angle | S | • | • | • | • | • | • | • | • | • | ||||||||||
2.25 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC2M25CP-2 | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | • | ||||||||||
TXC2M25EP-2 | 1/2″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
3.50 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC3M50EP-1 | 1/2″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | • | ||||||||
5.00 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC5M00BP-4 | 3/16″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | |||||||||
TXC5M00CP-4 | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | • | ||||||||||
TXC5M00BP-6 | 1/4″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | |||||||||
TXC5M00CP-8 | 1/4″ | High Temp | HD | • | • | • | • | • | • | • | • | • | ||||||||||
TXC5M00EP-3 | 1/2″ | Right Angle | S | • | • | • | • | • | • | • | • | • | ||||||||||
TXC5M00EP-4 | 1/2″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | |||||||||
7.50 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC7M50BP-3 | 3/16″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | • | ||||||||
TXC7M50CP-4 | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | • | • | |||||||||
TXC7M50CP-5 | 1/4″ | Right Angle | CT, HD | • | • | • | • | • | • | • | • | • | • | • | ||||||||
10.0 MHz Dual Element Thickness Transducer |
||||||||||||||||||||||
TXC10M0BP-1 | 3/16″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
TXC10M0CP-4 | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
15.0 MHz Single Element Transducer |
||||||||||||||||||||||
TXC15M0CM | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
20.0 MHz Single Element Transducer |
||||||||||||||||||||||
TXC20M0CM | 1/4″ | Right Angle | S | • | • | • | • | • | • | • | • | |||||||||||
Delay Lines |
||||||||||||||||||||||
Each gauge is supplied with 9mm and 12mm acrylic delay lines suitable for measuring on steel, aluminum and titanium. If measuring on thin plastics using Plastic Mode (PLAS), a graphite delay line must be used. These are available to purchase as optional accessories. |
||||||||||||||||||||||
Part Number | Description | |||||||||||||||||||||
T92016528 | Acrylic Delay Line; 1/4 Dia x 9mm | |||||||||||||||||||||
T92016529 | Acrylic Delay Line; 1/4 Dia x 12mm | |||||||||||||||||||||
T92023853-4 | Graphite Delay Line; 1/4 Dia x 3/16″ | |||||||||||||||||||||
All transducers are supplied with a calibration certificate HD—Highly damped Transducer CT—Damped Coating Thickness Transducer S—–Standard undamped Transducer |