Elcometer Canadian Distributor

1 800 463-4363
My Account
|
Elcometer distributor - Test Coatings

Wet Paint Depth Gauge – Metric | Elcometer 3230

$402.30 CAD$799.02 CAD

 

• Accurate wet film thickness gauge for the coil coating process.

 

The Elcometer 3230 Wet Film Wheels Set is a high precision, accurate and easy to use wet paint thickness gauge which consists of a set of three wheels.

It is important that a coating is applied to the correct thickness. Applying too much wet coating will not only waste and money, but also there is also a possibility of the coating cracking during the curing process. Too little coating and there is a chance that the substrate will not be sufficiently covered. To control process variables, it is often desirable to measure whilst the film is still wet. Wet film measurements are also useful for systems where the dry film thickness can only be measured destructively. Imperial version available here!

By rolling the gauge through a wet coating, the center wheel eventually touches the film. This point on the scale indicates the thickness.

A convenient mounting handle for the wheel is available in two lengths; 15cm (6″) & 50cm (19″); please order separately.

When the volume to solids ratio of the coating is known (generally found on the product data sheet supplied by the manufacturer), the wet film thickness can be used to predict the dry film thickness.

Several measurement ranges between 0 to 25µm and 0 to 3000µm (0 to 1mil and 0 to 40mils) are available.

  • Continuous scale produces ±5% measurement accuracy
  • Suitable for flat and curved surfaces

Using a wet film wheel:

Roll the wheel through a wet coating, the center wheel eventually touches the film. This point on the scale indicates the thickness. When the volume to solids ratio of the coating is known, generally found on a product data sheet, the wet film thickness can be used to predict the dry film thickness. To use wheel on pipes, measure across the longitudinal axis (lengthways) of the pipe. On rough surfaces, measurements will be made from the surface peaks and represent the minimum wet film thickness.

The Elcometer 3230 central wheel is of a smaller diameter and is eccentric relative to the two outer wheels.


Technical Specifications – Elcometer 3230 Wet Film Wheels (Metric)
Part Number Metric
Scale Range Graduations
K0003230M001 0 – 25µm 1.25µm
K0003230M016 0 – 40µm 2.0µm
K0003230M002 0 – 50µm 2.5µm
K0003230M003 0 – 100µm 5.0µm
K0003230M004 0 – 150µm 7.5µm
K0003230M005 0 – 200µm 10.0µm
K0003230M006 0 – 250µm 12.5µm
K0003230M007 0 – 300µm 15.0µm
K0003230M008 0 – 400µm 20.0µm
K0003230M009 0 – 500µm 25.0µm
K0003230M010 0 – 1000µm 50.0µm
K0003230M015 0 – 1500µm 75.0µm
K0003230M011 0 – 2000µm 100µm
K0003230M012 0 – 3000µm 150µm
Dimensions 50 x 30mm (1.97 x 1.18″)
Weight 220g (7.76oz)
Certificate available Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability. Accredited Certificate: can be issued for Fixed Calibration Equipment and a full UKAS traceable certificate is issued from an independent Calibration Laboratory.
Packing List
  • Wet Film Wheel
  • storage case
  • operating instructions

Can be used in accordance with:

ASTM D 1212-A, AS/NZS 1580.107.3BS 3900-C5-7AISO 2808-1BISO 2808-7AJIS K 5600-1-7, NF T30-125

Wet Film Wheels – Imperial | Elcometer 3230

The Elcometer 3230 Wet Film Wheels Set is a high precision, accurate and easy to use wet paint thickness gauge which consists of a set of three wheels.

It is important that a coating is applied to the correct thickness. Applying too much wet coating will not only waste and money, but also there is also a possibility of the coating cracking during the curing process. Too little coating and there is a chance that the substrate will not be sufficiently covered. To control process variables, it is often desirable to measure whilst the film is still wet. Wet film measurements are also useful for systems where the dry film thickness can only be measured destructively. Imperial version available here!

By rolling the gauge through a wet coating, the center wheel eventually touches the film. This point on the scale indicates the thickness.

A convenient mounting handle for the wheel is available in two lengths; 15cm (6″) & 50cm (19″); please order separately.

When the volume to solids ratio of the coating is known (generally found on the product data sheet supplied by the manufacturer), the wet film thickness can be used to predict the dry film thickness.

Several measurement ranges between 0 to 25µm and 0 to 3000µm (0 to 1mil and 0 to 40mils) are available.

  • Continuous scale produces ±5% measurement accuracy
  • Suitable for flat and curved surfaces

Using a wet film wheel:

Roll the wheel through a wet coating, the center wheel eventually touches the film. This point on the scale indicates the thickness. When the volume to solids ratio of the coating is known, generally found on a product data sheet, the wet film thickness can be used to predict the dry film thickness. To use wheel on pipes, measure across the longitudinal axis (lengthways) of the pipe. On rough surfaces, measurements will be made from the surface peaks and represent the minimum wet film thickness.

The Elcometer 3230 central wheel is of a smaller diameter and is eccentric relative to the two outer wheels.


Technical Specifications – Elcometer 3230 Wet Film Wheels (Metric)
Part Number Metric
Scale Range Graduations
K0003230M001 0 – 25µm 1.25µm
K0003230M016 0 – 40µm 2.0µm
K0003230M002 0 – 50µm 2.5µm
K0003230M003 0 – 100µm 5.0µm
K0003230M004 0 – 150µm 7.5µm
K0003230M005 0 – 200µm 10.0µm
K0003230M006 0 – 250µm 12.5µm
K0003230M007 0 – 300µm 15.0µm
K0003230M008 0 – 400µm 20.0µm
K0003230M009 0 – 500µm 25.0µm
K0003230M010 0 – 1000µm 50.0µm
K0003230M015 0 – 1500µm 75.0µm
K0003230M011 0 – 2000µm 100µm
K0003230M012 0 – 3000µm 150µm
Dimensions 50 x 30mm (1.97 x 1.18″)
Weight 220g (7.76oz)
Certificate available Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability. Accredited Certificate: can be issued for Fixed Calibration Equipment and a full UKAS traceable certificate is issued from an independent Calibration Laboratory.
Packing List
  • Wet Film Wheel
  • storage case
  • operating instructions

Can be used in accordance with:

ASTM D 1212-A, AS/NZS 1580.107.3BS 3900-C5-7AISO 2808-1BISO 2808-7AJIS K 5600-1-7, NF T30-125

Wet Film Wheels – Imperial | Elcometer 3230