Measure Dew Point and climatic conditions for painted surfaces. Works as a hand-held gauge / stand-alone data logger
Multi-lingual, large and easy to use illuminated display. Record climatic parameters and store 25,000 records in up to 999 batches. No need to sift through tables or use a dew point calculator. USB / Bluetooth data output.
ELCOMETER 319 MODEL SPECS
Standard Gauge Model S 10 records reading rolling memory
Top Gauge Model B – Stores 25,000 records in up to 999 batches. Bluetooth-enabled. ElcoMaster® software & USB cable included.
SELECT YOUR MODEL ON TOP OF THE PAGE TO VIEW THE PRICE
Confrms to the following standards:
BS 7079-B4, IMO MSC.215(82), IMO MSC.244(83), ISO 8502-4, US Navy NSI 009-32, US Navy PPI 63101-000
Elcometer 319 – dew point meter with a great price
- Integrated magnets = remote data monitoring on steel substrates
- Store 25,000 records in up to 999 batches
- USB and Bluetooth data output to a PC or PDA
- Dustproof and waterproof gauge with fully sealed sensors (equivalent to IP66)
- User-defined alarm for any parameter
- Multi-lingual menu
- Manual and interval data logging
- Measure and record climatic parameters:
- RH: % Relative Humidity
- Ts: Surface Temperature
- Ta: Ambient Air Temperature
- Td: Dewpoint Temperature
- TΔ: the difference between the Td and Ts
- Tdb: Dry Bulb Temperature
- Twb: Wet Bulb Temperature
- SH: Specific Humidity
Remote logging
- Use it as a hand-held Dewpoint meter or a remote data logging monitor (model T only)
- Integrated K-Type connector allows measurement of surface temperature during remote logging
- “Te” mode transforms the dew point meter into a simple thermometer for coating’s temperature
- Hold/freeze function – review manual readings before logging.
Great tool for harsh environment
- Temperature resistant materials for climates ranging between -20°C (-4°F) and +80°C (+176°F)
- Waterproof and dustproof rating equivalent to IP66
- Durable industrial sensors ideal for harsh environments
- Large display for full temperature range
Versatile ElcoMaster 2.0 Software
- Data download to PC via USB or Bluetooth
- “Watchguard” functionality monitors up to 42 gauges on one screen*
- Unit is powered by batteries or USB
- Set alarms for any parameter
| Back to Top |
Model | Model S | Model T | Certificate |
Part Number | G319—-S | G319—-T | |
Reading Parameters – RH, Ta, Ts (Te6), Td, TΔ, Tdb, Twb1, SH1 | ● | ● | |
Statistics – number of readings, standard deviation, mean, coefficient of variation, minimum, maximum | ● | ● | |
Dustproof & waterproof with fully sealed sensors – equivalent to IP66 | ● | ● | |
Integral Magnets – secure the gauge during logging | ● | ● | |
High/Low Limits – audible, visual, red/green LED alarms can be set against any or all parameters | ● | ● | |
Multilingual Menus | ● | ● | |
Backlight – user selectable | ● | ● | |
K-Type Connector for external probes | ● | ● | |
Memory – with reading and statistic review | Last 10 records | 25,000 records in 999 batches | |
Manual Logging | ● | ● | |
Interval Logging2 | Adjustable between 1 second and 24 hours | ||
*Data Output* | |||
USB | ● | ||
Bluetooth® to computer, Android™ & iOS4 devices | ● | ||
ElcoMaster® software & USB cable | ● | ||
Temperature Range | Accuracy | Resolution | |
Gauge5 | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
Air Temperature (Ta) | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F)7 | 0.1°C (0.1°F) |
Surface Temperature (TS) | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
External K-Type Thermocouple (Te) | -40 to +200°C (-40 to+392°F) | ±0.5°C (±1°F)6 | 0.1°C (0.1°F) |
Relative Humidity (RH) | 0 to 100%RH | ±3%RH3 | 0.1% |
Gauge & LCD Operating Range | -20°C to +80°C (-4°F to +176°F) | ||
Power Supply | 2 x AA batteries or via USB Cable | ||
Battery Life | Manual Mode: Greater than 40 hours (Backlight Off) Interval Logging: up to 400 hours (1 reading every 10 minutes) |
||
Dimensions | 180 x 75 x 35mm (7 x 3 x 1.4”) | ||
Weight | 300g (0.66lb) | ||
Packing List | Elcometer 319 Dewpoint Meter, 2 x AA batteries, wrist strap, carry case, calibration certificate, USB cable8, ElcoMaster®8 and operating instructions |
Elcometer 319 in action – checking humidity
| Back to Top |
Model Elcometer 319 | Standard Gauge | Top Gauge | |
Part Number | G319—-S | G319—-T | |
Reading Parameters – RH, Ta, Ts, Td, TΔ, Tdb, Twb, SH1 | • | • | |
Statistics – number of readings, standard deviation, mean, coefficient of variation, minimum, maximum |
• | • | |
Dustproof & Waterproof Gauge with Fully Sealed Sensors – equivalent to IP66 |
• | • | |
Integral Magnets – secure the gauge during logging | • | • | |
High/Low Limits – audible, visual, red/green LED alarms can be set against any or all parameters |
• | • | |
Multi-Language Menus | • | • | |
Backlight- user selectable | • | • | |
K-Type Connector for External Measurement | • | • | |
Memory – with reading and statistic review | Last 10 records | 25,000 records in 999 batches | |
Manual Logging | • | • | |
Interval Logging | Adjustable between 1 second and 1 hour | ||
USB and Bluetooth Wireless Data Output | • | ||
ElcoMaster & ElcoMaster Mobile Software | • | ||
Temperature Range | Accuracy | Resolution | |
Gauge# | -40 to +200ºC (-40 to +392ºF) | ±0.5ºC (±1ºF) | 0.1ºC (0.1ºF) |
Air Temperature (Ta) | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
Surface Temperature (Ts) | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
External K-Type Thermocouple (Te)# | -20 to +80ºC (-4 to +176ºF) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
Relative Humidity (RH) | 0 to 100%RH | ±3%RH | 0.1% |
Gauge & LCD Operating Range | -20°C to +80°C (-4°F to +176°F) | ||
Power Supply | 2 x AA 1.5V Batteries or via USB Cable | ||
Battery Life | Manual Mode: Greater than 40 hours (Backlight Off) Interval Logging: up to 400 hours (1 reading every 10 minutes) |
||
Dimensions | 180 x 75 x 35mm (7 x 3 x 1.4”) | ||
Weight | 300g (0.66lb) | ||
Certificate available | Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability. | ||
Packing List | Elcometer 319 Dewpoint Meter, 2 x AA batteries, wrist strap, carry case, calibration certificate, USB cable+, ElcoMaster™& ElcoMaster™Mobile Software+ |
SLASH YOUR COSTS BY GETTING A KIT:
FERROUS / NON-FERROUS METAL INSPECTION KIT | LARGER PROJECTS INSPECTION KIT 5
Top Gauge
(Stores 25,000 records in up to 999 batches. Bluetooth-enabled. ElcoMaster® software & USB cable included.)
Standard Gauge
(10 records reading rolling memory)| Back to Top |
Measure Dew Point and climatic conditions for painted surfaces. Works as a hand-held gauge / stand-alone data logger
Multi-lingual, large and easy to use illuminated display. Record climatic parameters and store 25,000 records in up to 999 batches. No need to sift through tables or use a dew point calculator. USB / Bluetooth data output.
ELCOMETER 319 MODEL SPECS
Standard Gauge Model S 10 records reading rolling memory
Top Gauge Model B – Stores 25,000 records in up to 999 batches. Bluetooth-enabled. ElcoMaster® software & USB cable included.
SELECT YOUR MODEL ON TOP OF THE PAGE TO VIEW THE PRICE
Confrms to the following standards:
BS 7079-B4, IMO MSC.215(82), IMO MSC.244(83), ISO 8502-4, US Navy NSI 009-32, US Navy PPI 63101-000
Elcometer 319 – dew point meter with a great price
- Integrated magnets = remote data monitoring on steel substrates
- Store 25,000 records in up to 999 batches
- USB and Bluetooth data output to a PC or PDA
- Dustproof and waterproof gauge with fully sealed sensors (equivalent to IP66)
- User-defined alarm for any parameter
- Multi-lingual menu
- Manual and interval data logging
- Measure and record climatic parameters:
- RH: % Relative Humidity
- Ts: Surface Temperature
- Ta: Ambient Air Temperature
- Td: Dewpoint Temperature
- TΔ: the difference between the Td and Ts
- Tdb: Dry Bulb Temperature
- Twb: Wet Bulb Temperature
- SH: Specific Humidity
Remote logging
- Use it as a hand-held Dewpoint meter or a remote data logging monitor (model T only)
- Integrated K-Type connector allows measurement of surface temperature during remote logging
- “Te” mode transforms the dew point meter into a simple thermometer for coating’s temperature
- Hold/freeze function – review manual readings before logging.
Great tool for harsh environment
- Temperature resistant materials for climates ranging between -20°C (-4°F) and +80°C (+176°F)
- Waterproof and dustproof rating equivalent to IP66
- Durable industrial sensors ideal for harsh environments
- Large display for full temperature range
Versatile ElcoMaster 2.0 Software
- Data download to PC via USB or Bluetooth
- “Watchguard” functionality monitors up to 42 gauges on one screen*
- Unit is powered by batteries or USB
- Set alarms for any parameter
| Back to Top |
Model | Model S | Model T | Certificate |
Part Number | G319—-S | G319—-T | |
Reading Parameters – RH, Ta, Ts (Te6), Td, TΔ, Tdb, Twb1, SH1 | ● | ● | |
Statistics – number of readings, standard deviation, mean, coefficient of variation, minimum, maximum | ● | ● | |
Dustproof & waterproof with fully sealed sensors – equivalent to IP66 | ● | ● | |
Integral Magnets – secure the gauge during logging | ● | ● | |
High/Low Limits – audible, visual, red/green LED alarms can be set against any or all parameters | ● | ● | |
Multilingual Menus | ● | ● | |
Backlight – user selectable | ● | ● | |
K-Type Connector for external probes | ● | ● | |
Memory – with reading and statistic review | Last 10 records | 25,000 records in 999 batches | |
Manual Logging | ● | ● | |
Interval Logging2 | Adjustable between 1 second and 24 hours | ||
*Data Output* | |||
USB | ● | ||
Bluetooth® to computer, Android™ & iOS4 devices | ● | ||
ElcoMaster® software & USB cable | ● | ||
Temperature Range | Accuracy | Resolution | |
Gauge5 | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
Air Temperature (Ta) | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F)7 | 0.1°C (0.1°F) |
Surface Temperature (TS) | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
External K-Type Thermocouple (Te) | -40 to +200°C (-40 to+392°F) | ±0.5°C (±1°F)6 | 0.1°C (0.1°F) |
Relative Humidity (RH) | 0 to 100%RH | ±3%RH3 | 0.1% |
Gauge & LCD Operating Range | -20°C to +80°C (-4°F to +176°F) | ||
Power Supply | 2 x AA batteries or via USB Cable | ||
Battery Life | Manual Mode: Greater than 40 hours (Backlight Off) Interval Logging: up to 400 hours (1 reading every 10 minutes) |
||
Dimensions | 180 x 75 x 35mm (7 x 3 x 1.4”) | ||
Weight | 300g (0.66lb) | ||
Packing List | Elcometer 319 Dewpoint Meter, 2 x AA batteries, wrist strap, carry case, calibration certificate, USB cable8, ElcoMaster®8 and operating instructions |
Elcometer 319 in action – checking humidity
| Back to Top |
Model Elcometer 319 | Standard Gauge | Top Gauge | |
Part Number | G319—-S | G319—-T | |
Reading Parameters – RH, Ta, Ts, Td, TΔ, Tdb, Twb, SH1 | • | • | |
Statistics – number of readings, standard deviation, mean, coefficient of variation, minimum, maximum |
• | • | |
Dustproof & Waterproof Gauge with Fully Sealed Sensors – equivalent to IP66 |
• | • | |
Integral Magnets – secure the gauge during logging | • | • | |
High/Low Limits – audible, visual, red/green LED alarms can be set against any or all parameters |
• | • | |
Multi-Language Menus | • | • | |
Backlight- user selectable | • | • | |
K-Type Connector for External Measurement | • | • | |
Memory – with reading and statistic review | Last 10 records | 25,000 records in 999 batches | |
Manual Logging | • | • | |
Interval Logging | Adjustable between 1 second and 1 hour | ||
USB and Bluetooth Wireless Data Output | • | ||
ElcoMaster & ElcoMaster Mobile Software | • | ||
Temperature Range | Accuracy | Resolution | |
Gauge# | -40 to +200ºC (-40 to +392ºF) | ±0.5ºC (±1ºF) | 0.1ºC (0.1ºF) |
Air Temperature (Ta) | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
Surface Temperature (Ts) | -20 to +80°C (-4 to +176°F) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
External K-Type Thermocouple (Te)# | -20 to +80ºC (-4 to +176ºF) | ±0.5°C (±1°F) | 0.1°C (0.1°F) |
Relative Humidity (RH) | 0 to 100%RH | ±3%RH | 0.1% |
Gauge & LCD Operating Range | -20°C to +80°C (-4°F to +176°F) | ||
Power Supply | 2 x AA 1.5V Batteries or via USB Cable | ||
Battery Life | Manual Mode: Greater than 40 hours (Backlight Off) Interval Logging: up to 400 hours (1 reading every 10 minutes) |
||
Dimensions | 180 x 75 x 35mm (7 x 3 x 1.4”) | ||
Weight | 300g (0.66lb) | ||
Certificate available | Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability. | ||
Packing List | Elcometer 319 Dewpoint Meter, 2 x AA batteries, wrist strap, carry case, calibration certificate, USB cable+, ElcoMaster™& ElcoMaster™Mobile Software+ |
SLASH YOUR COSTS BY GETTING A KIT:
FERROUS / NON-FERROUS METAL INSPECTION KIT | LARGER PROJECTS INSPECTION KIT 5
Top Gauge
(Stores 25,000 records in up to 999 batches. Bluetooth-enabled. ElcoMaster® software & USB cable included.)
Standard Gauge
(10 records reading rolling memory)| Back to Top |