Elcometer Canadian Distributor

1 800 463-4363
My Account
|
Elcometer Canada

MTG2 Ultrasonic Material Thickness Gauge with Transducer

$2,057.69 CAD

Support, maintenance, calibration
1 800 463-4363

 

Ergonomic, rugged, accurate and easy to use, the Elcometer MTG & PTG range of ultrasonic Material and Precision thickness gauges is ideal for measuring and recording material thickness from just 0.15mm (0.006″) to 500mm (20″)

With automatic transducer recognition which ensures correct probe identification even when the Ultrasonic Material Thickness Gauge MTG2 is changed, a measurement rate of 4Hz (4 readings per second) and integral zero disc ensuring maximum accuracy of ±1%, the MTG2 is ideal for taking basic thickness measurements.

Factory calibrated for use on steel.

The MTG2 is supplied complete with 5MHz, ¼” transducer and is pre-calibrated for measuring on steel only with a thickness range of up to 500mm (20”) in Pulsed-Echo (P-E) mode.

Compatible with ElcoMaster™ software, individual readings can be downloaded via USB to PC or similar device for further analysis.

With a scratch and solvent resistant display, sealed, heavy duty and impact resistant design – dust and waterproof equivalent to IP54 – the MTG and PTG range is suitable for use in the harshest of environments.

The Elcometer NDT MTG range has a number of measurement modes available to help the user establish the most accurate thickness value. The modes available vary between models but normally increase as the model number increases.

SLASH YOUR COSTS BY GETTING A COMPLETE KIT:

LARGER PROJECTS INSPECTION KIT 5  |  SEE OTHER KITS AVAILABLE

Key features

Pulsed – Echo Mode (P-E):

Ideal for pit and flaw detection, the total thickness from the base of the transducer to the material density boundary (typically the back-wall) is measured.
larger projects Inspection Kit 5
View Technical Specifications

Product Accessories

Dual & Single Element Transducers

Connector Type Suitable for Measuring Suitable For
Part Number
Probe Diameter
Probe Configuration
Damping
ThruPaintTM
Potted Right Angle
Microdot
Cast Iron
Plastics
Thin Plastics
Fiberglass
Thin Fiberglass
Steel
Glass
Aluminium
Titanium
MTG2
MTG4
MTG6
MTG8
PTG6
PTG8
Calibration Certificate

1.00 MHz Dual Element Thickness Transducer

TXC1M00EP-2 1/2″ Right Angle S

2.25 MHz Dual Element Thickness Transducer

TXC2M25CP-2 1/4″ Right Angle S
TXC2M25EP-2 1/2″ Right Angle S

3.50 MHz Dual Element Thickness Transducer

TXC3M50EP-1 1/2″ Right Angle CT, HD

5.00 MHz Dual Element Thickness Transducer

TXC5M00BP-4 3/16″ Right Angle CT, HD
TXC5M00CP-4 1/4″ Right Angle S
TXC5M00BP-6 1/4″ Right Angle CT, HD
TXC5M00CP-8 1/4″ High Temp HD
TXC5M00EP-3 1/2″ Right Angle S
TXC5M00EP-4 1/2″ Right Angle CT, HD

7.50 MHz Dual Element Thickness Transducer

TXC7M50BP-3 3/16″ Right Angle CT, HD
TXC7M50CP-4 1/4″ Right Angle S
TXC7M50CP-5 1/4″ Right Angle CT, HD

10.0 MHz Dual Element Thickness Transducer

TXC10M0BP-1 3/16″ Right Angle S
TXC10M0CP-4 1/4″ Right Angle S

15.0 MHz Single Element Transducer

TXC15M0CM 1/4″ Right Angle S

20.0 MHz Single Element Transducer

TXC20M0CM 1/4″ Right Angle S

Delay Lines

Each gauge is supplied with 9mm and 12mm acrylic delay lines suitable for measuring on steel, aluminum and titanium.
If measuring on thin plastics using Plastic Mode (PLAS), a graphite delay line must be used. These are available to purchase as optional accessories.
Part Number Description
T92016528 Acrylic Delay Line; 1/4 Dia x 9mm
T92016529 Acrylic Delay Line; 1/4 Dia x 12mm
T92023853-4 Graphite Delay Line; 1/4 Dia x 3/16″
All transducers are supplied with a calibration certificate
HD—Highly damped Transducer
CT—Damped Coating Thickness Transducer
S—–Standard undamped Transducer

Download Data Sheet

Standards

Can be used in accordance with:

ASTM E797, EN 14127, EN15317

 

1-Free-shipping

Ergonomic, rugged, accurate and easy to use, the Elcometer MTG & PTG range of ultrasonic Material and Precision thickness gauges is ideal for measuring and recording material thickness from just 0.15mm (0.006″) to 500mm (20″)

With automatic transducer recognition which ensures correct probe identification even when the Ultrasonic Material Thickness Gauge MTG2 is changed, a measurement rate of 4Hz (4 readings per second) and integral zero disc ensuring maximum accuracy of ±1%, the MTG2 is ideal for taking basic thickness measurements.

Factory calibrated for use on steel.

The MTG2 is supplied complete with 5MHz, ¼” transducer and is pre-calibrated for measuring on steel only with a thickness range of up to 500mm (20”) in Pulsed-Echo (P-E) mode.

Compatible with ElcoMaster™ software, individual readings can be downloaded via USB to PC or similar device for further analysis.

With a scratch and solvent resistant display, sealed, heavy duty and impact resistant design – dust and waterproof equivalent to IP54 – the MTG and PTG range is suitable for use in the harshest of environments.

The Elcometer NDT MTG range has a number of measurement modes available to help the user establish the most accurate thickness value. The modes available vary between models but normally increase as the model number increases.

SLASH YOUR COSTS BY GETTING A COMPLETE KIT:

LARGER PROJECTS INSPECTION KIT 5  |  SEE OTHER KITS AVAILABLE

Key features

Pulsed – Echo Mode (P-E):

Ideal for pit and flaw detection, the total thickness from the base of the transducer to the material density boundary (typically the back-wall) is measured.
larger projects Inspection Kit 5
View Technical Specifications

Product Accessories

Dual & Single Element Transducers

Connector Type Suitable for Measuring Suitable For
Part Number
Probe Diameter
Probe Configuration
Damping
ThruPaintTM
Potted Right Angle
Microdot
Cast Iron
Plastics
Thin Plastics
Fiberglass
Thin Fiberglass
Steel
Glass
Aluminium
Titanium
MTG2
MTG4
MTG6
MTG8
PTG6
PTG8
Calibration Certificate

1.00 MHz Dual Element Thickness Transducer

TXC1M00EP-2 1/2″ Right Angle S

2.25 MHz Dual Element Thickness Transducer

TXC2M25CP-2 1/4″ Right Angle S
TXC2M25EP-2 1/2″ Right Angle S

3.50 MHz Dual Element Thickness Transducer

TXC3M50EP-1 1/2″ Right Angle CT, HD

5.00 MHz Dual Element Thickness Transducer

TXC5M00BP-4 3/16″ Right Angle CT, HD
TXC5M00CP-4 1/4″ Right Angle S
TXC5M00BP-6 1/4″ Right Angle CT, HD
TXC5M00CP-8 1/4″ High Temp HD
TXC5M00EP-3 1/2″ Right Angle S
TXC5M00EP-4 1/2″ Right Angle CT, HD

7.50 MHz Dual Element Thickness Transducer

TXC7M50BP-3 3/16″ Right Angle CT, HD
TXC7M50CP-4 1/4″ Right Angle S
TXC7M50CP-5 1/4″ Right Angle CT, HD

10.0 MHz Dual Element Thickness Transducer

TXC10M0BP-1 3/16″ Right Angle S
TXC10M0CP-4 1/4″ Right Angle S

15.0 MHz Single Element Transducer

TXC15M0CM 1/4″ Right Angle S

20.0 MHz Single Element Transducer

TXC20M0CM 1/4″ Right Angle S

Delay Lines

Each gauge is supplied with 9mm and 12mm acrylic delay lines suitable for measuring on steel, aluminum and titanium.
If measuring on thin plastics using Plastic Mode (PLAS), a graphite delay line must be used. These are available to purchase as optional accessories.
Part Number Description
T92016528 Acrylic Delay Line; 1/4 Dia x 9mm
T92016529 Acrylic Delay Line; 1/4 Dia x 12mm
T92023853-4 Graphite Delay Line; 1/4 Dia x 3/16″
All transducers are supplied with a calibration certificate
HD—Highly damped Transducer
CT—Damped Coating Thickness Transducer
S—–Standard undamped Transducer

Download Data Sheet

Standards

Can be used in accordance with:

ASTM E797, EN 14127, EN15317

 