Elcometer Canadian Distributor

1 800 463-4363
My Account
|
Elcometer Canada

Elcometer 456 Probe Range | Anodizer Probes

$1,101.95 CAD

SKU: T456CN1AS Category: Tags: , , ,

All Elcometer 456 probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application

Ferrous probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.

Unless stated, Elcometer separate probes have a maximum operating temperature of 150°C (300°F), PINIP™ probes have a maximum operating temperature of 80°C (176°F).

Every Elcometer 456 gauge and separate probe is supplied with a Test Certificate free of charge. For separate gauges, the test measurements are generated using factory reference probes.

Need more information? Read our page on choosing the correct probe for coating substrates.

Anodizer Probes

Probes with metal reinforced heavy duty cables, reducing the risk of cable damage.

Ferrous probes measure non magnetic coatings on ferro-magnetic substrates Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous application with automatic substrate detection.
Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.
Elcometer probes have a maximum operating temperature of 80° C (176° F) with the exception of separate ferrous probes 150° C (300° F) and Hi-Temperature PINIP’s 250° C (480° F).
The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.

All Elcometer probes are supplied with a test certificate and a set of calibration foils appropriate to the scale range of the probe.

 

Product Description

Designed to work with any of our Non-Ferrous or Dual FNF Elcometer 456 Separate Gauges.

Chemical resistant washable probe ideal for Type II and Type III anodizing environments. Removable probe sleeve makes cleaning anodizing residue from probe fast and easy.

Specifications:

  • Range: 0-60 mils (0-1500µm)
  • Accuracy: ±1-3% or ±0.1 mil (±2.5µm)
  • Resolution: 0.01 mil: 0-5 mils; 0.1mil: 5-60 mils (0.1µm: 0-100µm; 1µm: 100-1500µm)
  • Minimum convex surface radius 10mm (0.39″)
  • Minimum concave surface radius 14mm (0.55″)
  • Minimum headroom 100mm (3.94″)
  • Minimum sample diameter 4mm (0.16″)

Specifications:

    • Range: 0-60 mils (0-1500µm)

Data sheet

1-Free-shipping

All Elcometer 456 probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application

Ferrous probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.

Unless stated, Elcometer separate probes have a maximum operating temperature of 150°C (300°F), PINIP™ probes have a maximum operating temperature of 80°C (176°F).

Every Elcometer 456 gauge and separate probe is supplied with a Test Certificate free of charge. For separate gauges, the test measurements are generated using factory reference probes.

Need more information? Read our page on choosing the correct probe for coating substrates.

Anodizer Probes

Probes with metal reinforced heavy duty cables, reducing the risk of cable damage.

Ferrous probes measure non magnetic coatings on ferro-magnetic substrates Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous application with automatic substrate detection.
Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.
Elcometer probes have a maximum operating temperature of 80° C (176° F) with the exception of separate ferrous probes 150° C (300° F) and Hi-Temperature PINIP’s 250° C (480° F).
The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.

All Elcometer probes are supplied with a test certificate and a set of calibration foils appropriate to the scale range of the probe.

 

Product Description

Designed to work with any of our Non-Ferrous or Dual FNF Elcometer 456 Separate Gauges.

Chemical resistant washable probe ideal for Type II and Type III anodizing environments. Removable probe sleeve makes cleaning anodizing residue from probe fast and easy.

Specifications:

  • Range: 0-60 mils (0-1500µm)
  • Accuracy: ±1-3% or ±0.1 mil (±2.5µm)
  • Resolution: 0.01 mil: 0-5 mils; 0.1mil: 5-60 mils (0.1µm: 0-100µm; 1µm: 100-1500µm)
  • Minimum convex surface radius 10mm (0.39″)
  • Minimum concave surface radius 14mm (0.55″)
  • Minimum headroom 100mm (3.94″)
  • Minimum sample diameter 4mm (0.16″)

Specifications:

    • Range: 0-60 mils (0-1500µm)

Data sheet

1-Free-shipping