Elcometer Canadian Distributor

1 800 463-4363
My Account
|
Elcometer distributor - Test Coatings

Bench Top Ultrasonic Flaw Detection Gauge

$13,438.50 CAD

  • Fast and accurate flaw detection
  • Ideal for weld inspection, forgings, or composite material testing
  • Battery life: 12 hours
SKU: FD800DL+ Categories: ,

The bench-top FDL800+ flaw detectors series combine state-of-the-art flaw detection with advanced material thickness capabilities.

With all the functionality of the top-of-the-range material thickness gauge, the FD800+ series, when in flaw detection mode offers a variety of tool kits that enable fast and accurate flaw detection, ideal for weld inspection, forgings, or composite material testing.

Tool kits include:

  1. TRIG enabling the location of flaws in both surface distance and depth.
  2. DAC for the creation of DAC curves which are used to inform the operator of the size of any given flaw at any depth.
  3. AWS function provides automatic defect sizing in accordance with AWS D1.1 structural welding code.
  4. AVG/DGS allows automatic defect sizing using probe data, storing up to 64 custom setups.
  5. TCG (time corrected gain) increases gain as distance increases, in order to achieve an overall level of sensitivity for the same flaw/reflector at different distances.

Advantages

  1. Blanview sunlight-readable QVGA TFT color display
  2. Sizing Toolkits: DAC, AWS, TCG, DGS
  3. Pulse Repetition Frequency: 8 to 333 Hz, adjustable
  4. Screen Refresh Rate: Adjustable 60 Hz
  5. Detection: Z-Cross, Flank & Peak
  6. Automatic: probe zero, probe recognition, and temperature compensation
  7. Measurement: Variety of modes to address a number of applications
  8. Large data storage: 6Gb internal & up to 64Gb external SD slot
  9. Multiple formats: Alpha numeric grid and sequential w/auto identifier
  10. Up to 12 hours of battery life
  11. Data management software
Model & Part Number FD800DL+ Bench Top Flaw Detection Gauge
Material thickness digits display
B-Scan cross-sectional display
B-Scan with digits display
Scan bar display
Coating thickness display
A-Scan display + Rectified, – Rectified, Full Waveform (RF)
Flaw detection modes TRIG, DAC, AWS, TCG, Zero Crossing, Flank, Peak
Measurement Mode PE, PETP (Temp Compensation),
EE (ThruPaint™), EEV, CT (Coating) & PECT
Measurement Rate (Thickness Mode)
Manual:
Scan mode
Scan bar display
4 readings per second
32 readings per second
6 readings per second
Measuring Range PE: 0.63 – 30480mm (0.025 – 1,200 inches)
PETP: 0.63 – 30480mm (0.025 – 1,200 inches)
EE: 1.27 – 102mm (0.050 – 4.000 inches)
EEV: 1.27 – 25.4mm (0.050 – 1.000 inch)
CT: 0.01 – 2.54mm (0.0005 – 0.100 inch)
PECT: 0.63 – 30480mm (0.025 – 1,200 inches)
PECT: 0.01 – 2.54mm (0.0005 – 0.100 inch)
Measurement Accuracy ±0.01mm (±0.001 inch)
Measurement Resolution 0.01mm (0.001 inch)
Velocity Calibration Range 256 – 16,000m/s (0.0100 – 0.6300in/ms)
Additional Features:
    High speed scan mode
    Differential mode
    Limit alarm mode
B-Scan display speed adjustable display speed
Calibration setups 6 factory & 64 user-definable setups
transferrable to and from a PC archive
Gates 3 fully adjustable gates:
start, stop, width & threshold
Damping adjustable; impedance matching for
optimizing transducer performance
Pulser type FD800DL+: two-tone burst pulsers
Gain manual, automatic gain control (AGC)
with 110dB range with 0.2dB resolution
Timing precision TCXO timing with a single shot
100MHz 8bit ultra-low-power digitizer
Data logging – 6Gb internal & up to 64Gb external SD slot
– Bitmap graphic capture
– sequential and grid logging
– Alphanumeric batch identification
– OBSTRUCT indicates inaccessible locations
Calibration Options single, two-point, velocity & material type
Transducer recognition automatic
V-path / dual path error correction automatic
Probe zero automatic
Flaw Detection Mode Features
Automatic
Calibration:
Longitudinal (straight),
or Shear (angle)
Probe Types: Single Contact, Dual, Delay & Angle
Material Velocity Table: Contains longitudinal and shear
velocities for a variety of material types
TRIG Trigonometric display of beam path,
depth, surface distance, and curved surface correction.
Used with angle beam transducers
DAC Up to 8 points may be entered and used to digitally
draw a DAC curve. Reference -2, -6, -10, (-6/-12),
(-6/-14), (-2/-6/-10) dB. Amplitude displayed in
%DAC, dB, or %FSH
AWS Automatic defect sizing in accordance with AWS
D1.1 structural welding code.
AVG/DGS Automatic defect sizing using a probe
data. Stores up to 64 custom setups
TCG Time corrected gain. 50 dB dynamic range, 20 dB
per microsecond, up to 8 points for curve definition
Detection Modes Zero-Crossing, Flank, and Peak
Display Freeze Hold current waveform on screen
Peak Memory Captures peak signal amplitude.
P.R.F 8 to 333Hz in selectable steps (8, 16, 32, 66, 125,
250, 333Hz)
Pulse Width 40 to 400 ns. Selectable step
options 40, 80 & 400 ns (labeled spike, thin &
wide)
Frequency Bands FD800DL & FD800DL+: Broadband 1.8 – 19 MHz (-3dB). Four narrow bands at 1, 2, 5, 10MHz
FD800DL: Additional narrow bands at 5MHz, 15MHz
Horizontal Linearity +/- 0.4% FSW
Vertical Linearity +/- 1% FSH
Amplifier Linearity +/- 1 dB
Amplitude Measurement 0 to 100% FSH, with 1% resolution
Delay 0 – 999in (25,375mm) at steel velocity
Display Blanview sunlight-readable QVGA TFT color display. 115.2 x 86.4mm (4.54 x 3.40 inches) viewable screen
Display Refresh Rate 60Hz
Units (selectable) mm or inches
Backlight adjustable brightness
Repeatability / Stability Indicator
Battery Type 6 x AA alkaline
Battery Life
(approximate)
12 hours
Low Battery Indicator
Battery Save Mode auto
Operating Temperature -10 to 60ºC (14 to 140ºF)
Size (w x h x d) 216.0 x 165.0 x 70.0mm
(8.5 x 6.5 x 2.5 inches)
Weight (including batteries) 2.04kg (4.5lbs)
Case Design Aluminum case design with the gasket-sealed end
caps, waterproof membrane keypad
Transducer Connector Type LEMO
RS232 Interface Bi-directional
Packing List Elcometer NDT FD800DL+ gauge, couplant, carry case, user manual, test certificate,
6 x AA batteries, ElcoMaster™ 2.0 software, transfer cable

Download Data Sheet

Download Instruction Manual

1-Free-shipping

The bench-top FDL800+ flaw detectors series combine state-of-the-art flaw detection with advanced material thickness capabilities.

With all the functionality of the top-of-the-range material thickness gauge, the FD800+ series, when in flaw detection mode offers a variety of tool kits that enable fast and accurate flaw detection, ideal for weld inspection, forgings, or composite material testing.

Tool kits include:

  1. TRIG enabling the location of flaws in both surface distance and depth.
  2. DAC for the creation of DAC curves which are used to inform the operator of the size of any given flaw at any depth.
  3. AWS function provides automatic defect sizing in accordance with AWS D1.1 structural welding code.
  4. AVG/DGS allows automatic defect sizing using probe data, storing up to 64 custom setups.
  5. TCG (time corrected gain) increases gain as distance increases, in order to achieve an overall level of sensitivity for the same flaw/reflector at different distances.

Advantages

  1. Blanview sunlight-readable QVGA TFT color display
  2. Sizing Toolkits: DAC, AWS, TCG, DGS
  3. Pulse Repetition Frequency: 8 to 333 Hz, adjustable
  4. Screen Refresh Rate: Adjustable 60 Hz
  5. Detection: Z-Cross, Flank & Peak
  6. Automatic: probe zero, probe recognition, and temperature compensation
  7. Measurement: Variety of modes to address a number of applications
  8. Large data storage: 6Gb internal & up to 64Gb external SD slot
  9. Multiple formats: Alpha numeric grid and sequential w/auto identifier
  10. Up to 12 hours of battery life
  11. Data management software
Model & Part Number FD800DL+ Bench Top Flaw Detection Gauge
Material thickness digits display
B-Scan cross-sectional display
B-Scan with digits display
Scan bar display
Coating thickness display
A-Scan display + Rectified, – Rectified, Full Waveform (RF)
Flaw detection modes TRIG, DAC, AWS, TCG, Zero Crossing, Flank, Peak
Measurement Mode PE, PETP (Temp Compensation),
EE (ThruPaint™), EEV, CT (Coating) & PECT
Measurement Rate (Thickness Mode)
Manual:
Scan mode
Scan bar display
4 readings per second
32 readings per second
6 readings per second
Measuring Range PE: 0.63 – 30480mm (0.025 – 1,200 inches)
PETP: 0.63 – 30480mm (0.025 – 1,200 inches)
EE: 1.27 – 102mm (0.050 – 4.000 inches)
EEV: 1.27 – 25.4mm (0.050 – 1.000 inch)
CT: 0.01 – 2.54mm (0.0005 – 0.100 inch)
PECT: 0.63 – 30480mm (0.025 – 1,200 inches)
PECT: 0.01 – 2.54mm (0.0005 – 0.100 inch)
Measurement Accuracy ±0.01mm (±0.001 inch)
Measurement Resolution 0.01mm (0.001 inch)
Velocity Calibration Range 256 – 16,000m/s (0.0100 – 0.6300in/ms)
Additional Features:
    High speed scan mode
    Differential mode
    Limit alarm mode
B-Scan display speed adjustable display speed
Calibration setups 6 factory & 64 user-definable setups
transferrable to and from a PC archive
Gates 3 fully adjustable gates:
start, stop, width & threshold
Damping adjustable; impedance matching for
optimizing transducer performance
Pulser type FD800DL+: two-tone burst pulsers
Gain manual, automatic gain control (AGC)
with 110dB range with 0.2dB resolution
Timing precision TCXO timing with a single shot
100MHz 8bit ultra-low-power digitizer
Data logging – 6Gb internal & up to 64Gb external SD slot
– Bitmap graphic capture
– sequential and grid logging
– Alphanumeric batch identification
– OBSTRUCT indicates inaccessible locations
Calibration Options single, two-point, velocity & material type
Transducer recognition automatic
V-path / dual path error correction automatic
Probe zero automatic
Flaw Detection Mode Features
Automatic
Calibration:
Longitudinal (straight),
or Shear (angle)
Probe Types: Single Contact, Dual, Delay & Angle
Material Velocity Table: Contains longitudinal and shear
velocities for a variety of material types
TRIG Trigonometric display of beam path,
depth, surface distance, and curved surface correction.
Used with angle beam transducers
DAC Up to 8 points may be entered and used to digitally
draw a DAC curve. Reference -2, -6, -10, (-6/-12),
(-6/-14), (-2/-6/-10) dB. Amplitude displayed in
%DAC, dB, or %FSH
AWS Automatic defect sizing in accordance with AWS
D1.1 structural welding code.
AVG/DGS Automatic defect sizing using a probe
data. Stores up to 64 custom setups
TCG Time corrected gain. 50 dB dynamic range, 20 dB
per microsecond, up to 8 points for curve definition
Detection Modes Zero-Crossing, Flank, and Peak
Display Freeze Hold current waveform on screen
Peak Memory Captures peak signal amplitude.
P.R.F 8 to 333Hz in selectable steps (8, 16, 32, 66, 125,
250, 333Hz)
Pulse Width 40 to 400 ns. Selectable step
options 40, 80 & 400 ns (labeled spike, thin &
wide)
Frequency Bands FD800DL & FD800DL+: Broadband 1.8 – 19 MHz (-3dB). Four narrow bands at 1, 2, 5, 10MHz
FD800DL: Additional narrow bands at 5MHz, 15MHz
Horizontal Linearity +/- 0.4% FSW
Vertical Linearity +/- 1% FSH
Amplifier Linearity +/- 1 dB
Amplitude Measurement 0 to 100% FSH, with 1% resolution
Delay 0 – 999in (25,375mm) at steel velocity
Display Blanview sunlight-readable QVGA TFT color display. 115.2 x 86.4mm (4.54 x 3.40 inches) viewable screen
Display Refresh Rate 60Hz
Units (selectable) mm or inches
Backlight adjustable brightness
Repeatability / Stability Indicator
Battery Type 6 x AA alkaline
Battery Life
(approximate)
12 hours
Low Battery Indicator
Battery Save Mode auto
Operating Temperature -10 to 60ºC (14 to 140ºF)
Size (w x h x d) 216.0 x 165.0 x 70.0mm
(8.5 x 6.5 x 2.5 inches)
Weight (including batteries) 2.04kg (4.5lbs)
Case Design Aluminum case design with the gasket-sealed end
caps, waterproof membrane keypad
Transducer Connector Type LEMO
RS232 Interface Bi-directional
Packing List Elcometer NDT FD800DL+ gauge, couplant, carry case, user manual, test certificate,
6 x AA batteries, ElcoMaster™ 2.0 software, transfer cable

Download Data Sheet

Download Instruction Manual

1-Free-shipping

Questions / comments: